Extron electronic MVX 84, MVX 88 Loading Firmware Using an SIS Command, Turn on the Echo Function

Models: 48 MVX 84 MVX 44 MVX 88

1 70
Download 70 pages 45.03 Kb
Page 50
Image 50
Loading Firmware Using an SIS Command

Loading Firmware Using an SIS Command

Figure 22. Turn on the Echo Function NOTE: Firmware can be uploaded two ways:

1. Using the Matrix Switchers Control Program.

2. Using the Eupload SIS command entered via a communications utility such as HyperTerminal.

Extron recommends that you upload firmware using the Matrix Switchers Control Program (see “Updating the firmware” on page 49) and reserve this SIS procedure for correcting firmware that has been corrupted and unable to respond to the Matrix Switchers Control Program.

Firmware can be loaded using SIS commands as follows:

1.Obtain the latest firmware file for the matrix switcher (see steps 1 through 6 of “Updating the firmware” on page 49.

2.Start a communications utility such as HyperTerminal. Select the Comm port that is connected to the RS-232 port of the switcher. Use 9600 bits per second, 8 data bits,

“none” parity, 1 stop bit, and “none” flow control.

Manual background NOTES: If you are performing this procedure to recover from corrupted firmware,

the switcher will respond only to the “n”, “q”, and “Eupload” SIS

commands.

The firmware upload can take several minutes. If the echo function of HyperTerminal is turned off, you will have no indication that the upload is progressing. If desired, turn on the echo function as follows (see figure 22): Click File > Properties > Settings > ASCII Setup..., check the Echo typed characters locally checkbox, and then click Ok twice.

Figure 22. Turn on the Echo Function

3.Depress the <Esc> key on the keyboard and then type upload. The computer responds with the Go prompt.

4.Click Transfer > Send text file... .

5.Click the Files of type: drop box and select All files (*.*).