6i Attach the safety cable to the PCM

h. Pass the safety cable through the anchor and attach it to

the center holes on either side of the plate. Ensure the

cable is of equal length on both sides of the anchor and secure the cable using the cable clamps.

Attach safety cable to center holes and secure with cable clamps.

TInstall any optional power outlets in the 2 gang opening on the mounting plate, towards the outside edge of the mount, so it does not interfere with the PMK 450 when installed.

CFor safety, all wiring of the electrical boxes and accessories should be completed after the plate is fully installed and secure.

6i Attach the safety cable to the PCM

PMK 450

Install power outlet in the 2-gang cutout (RACO box installed)

PCM 240

T-bar

(viewed from

 

above)

 

T Power outlet installation on the

PCM 240

7.Install the Screen

a.Following the screen manufacturers guidelines, continue to install the screen mounting brackets and then hang the screen.

TUse S-hooks to hang the screen from the brackets.

Bend the ends of the S-hooks so the screen does not fall when it is rolled up.