Faber FEELING, SPECTRA NOVA, WHISPER, SILENCE, MISTY Uk/Irl, Connection onto an existing chimney

Models: CADRA NOVA MISTY FEELING SILENCE SPECTRA NOVA WHISPER

1 29
Download 29 pages 61.36 Kb
Page 16
Image 16
5.2 Connection onto an existing chimney

UK/IRL

5.2 Connection onto an existing chimney

You can connect the appliance onto an existing chimney. The existing chimney then functions as air supply, where a flexible stainless steel liner (to BS715) of 100 mm performs the flue function. Any existing chimney used as an air supply must only service this appliance.

Requirements:

-300 mm of free space above the appliance;

-The chimney only supply’s air to this appliance;

-The existing chimney needs to be clean and very well swept;

-The existing chimney needs to be airtight;

-The existing chimney needs to have an opening of min. 150 x 150 mm.

 

 

Parts needed for this kind of installation:

 

 

- Chimney connection set

 

B

 

part number A9225000

Fig 20 part D

 

- Short roof terminal

 

 

 

 

A

 

part number A9266100

Fig 19 part B

 

- Chimney closure plate

 

 

 

 

 

 

part number A 9240000

Fig 19 part A

C

 

- Two stainless steel tubes one 100 mm -

 

 

length 500 mm and one 150 mm -

 

 

length 500 mm

 

 

 

part number A 9273900

Fig 19 part E and F

 

 

1. Place the aluminium closure plate (A) onto the

D

 

chimney. Permanently attach and make airtight.

F

 

2. Pull the liner (C) through the chimney.

E

 

3. Connect the liner onto the roof terminal and fix

 

 

 

 

this with the clamp provided with the chimney

 

 

connection set.

 

 

fig. 20

4. Place the roof terminal onto the closure plate.

 

 

 

UK/IRL

5.2Connection onto an existing chimney (continuing)

5.Fixing the chimney sealing plate (D) and place the 150 mm grommet into the hole of the sealing plate.

6.Fix the sealing plate air tight into the builders opening (use the isolation rope from the chimney connection set to make the plate air tight).

7.Slide the pipe (E) 150mm length 500mm into the sealing plate. Slide this pipe so far that you will have enough space later on for assembling the liner.

8.Install the appliance.

9.Connect the flexible stainless steel liner onto the appliance using the 100mm pipe (F) as adapter.

10.If the distance from the flue outlet to the sealing plate is bigger then 300 mm, you have to use a concentric pipe first.

11.Slide the outside pipe onto the appliance or concentric extension so that you have a air tight connection.

28

 

 

 

29

 

 

Page 16
Image 16
Faber FEELING, SPECTRA NOVA, WHISPER, SILENCE, MISTY, CADRA NOVA Uk/Irl, 5.2Connection onto an existing chimney continuing