Faber MISTY Uk/Irl, To extinguish, When the pilot extinguishes, Remote control version, To light

Models: CADRA NOVA MISTY FEELING SILENCE SPECTRA NOVA WHISPER

1 29
Download 29 pages 61.36 Kb
Page 27
Image 27
10.3 To extinguish

UK/IRL

10.3 To extinguish

1.For the main burner turn the control knob B clockwise to position {.

2.To disable knob B turn knob A to the 10.3.1 When the pilot extinguishes position.

3.To extinguish the pilot turn control knob A to position { , although it is in order lo leave the pilot permanently lit.

10.3.1 When the pilot extinguishes

Warning! When the pilot extinguishes, for whatever reason, you should wait at least 5 minutes before trying to turn it on again.

Possible causes of pilot extinguish are:

-Operating error.

-Interference of the safety device.

-Failure in the pilot flame system.

Contact a qualified installer when the appliance goes off regularly.

10.4 Remote control version

The remote control is only meant to regulate the flames from off till max., it functions only when the pilot burner is ignited and knob A in 10.4 Remote control version (big flame) position. It is therefore not possible to ignite the pilot flame with the remote control or to extinguish the pilot flame. The radio-frequency remote control is intended for fireplaces installed in a domestic setting in all EU countries except Austria, Denmark, Finland, and Greece.

Features:

-Manual control will always remain possible.

-The remote control is a radio frequency type and had been approved internationally.

-The remote control generates a unique safety code every time you activate the transmitter, its similar to those used in a car.

-The remote control is easy to install retrospectively.

UK/IRL

10.4.1 To light

1.Push in and turn the control knob (A) from { anticlockwise to the setting 10.4.1 To light (small flame). You will hear a ignition click. Check that the pilot is lit (if not repeat).

2. Continue to hold in the control knob for a further ten seconds to ensure that the pilot flame is stable.

3.Release the knob. The pilot should remain alight.

4.Turn the control knob A to the 10.4.2To extinguish position.

5.Set the on/off switch on the receiver to "on”.

Manual background low flame

Manual background high flame

6.Use Manual background (high) and Manual background (low) to achieve the desired heating and flame effect.

fig. 28

remote control 7. You will hear a beep every time the receiver recognises a good signal. (If not, so see 10.4.3, setting the right transmission code).

8.When the fire is not be used for a prolonged period, turn off the pilot (see 10.4.2).

10.4.2To extinguish

1.Push Manual background (low) till the burner goes out and you can hear the motor clicking.

2.To enable the remote control turn knob A to the Manual background position.

3.To extinguish the pilot turn control knob A to position {, although it is in order to leave the pilot permanently lit.

50

 

 

 

51

 

 

Page 27
Image 27
Faber MISTY, SPECTRA NOVA Uk/Irl, When the pilot extinguishes, Remote control version, To light, 10.4.2To extinguish