10. CONTROLLING THE APPLIANCE

UK/IRL

 

 

 

UK/IRL

10. CONTROLLING THE APPLIANCE

10.1 Lighting the fire

If the main burner or pilot light are extinguished for any reason, do not attempt to relight the pilot within 5 minutes. Contact a qualified installer when the appliance goes off regularly.

The control valve is behind the ashtray door.

Silence /Feeling /Whisper

Open the ashtray door by pushing on the right side for the

Silence/Feeling and on the left side for the Whisper.

Misty

Open the ashtray door by pulling down (bottom handle with gas damper).

Cadra Nova and Spectra Nova

Open by pushing the lip located on the right side in the gap between the ashtray door and the frame (door flaps open).

AB

fig. 27 control unit

With control button A you can light the pilot. With the control button B you can adjust the height of the flames (see fig. 27).

Knob A

The { is the OFF position preventing any gas from passing through the control valve to either the pilot burner or to the main burner. By pressing the knob in it is possible to turn it anticlockwise. The first function is to turn on the gas to the pilot- this occurs just before reaching the position (if the fire has not been lit for some time it may be necessary to hold the knob in this position for some seconds to clear the air from the pipe and allow gas to reach the pilot burner). Once gas is available at the pilot, continued rotation anti-clockwise will cause the piezo igniter to spark. This is accompanied by a click at the valve and should result in the pilot burner igniting. Once the pilot is lit, the control knob should be held pressed in for 10 seconds. In this time the pilot flame will have heated the flame supervision thermocouple sufficiently to operate a hold- on magnet within the valve. Now turn the control knob A to the

10.1 Lighting the fire position. This allows gas to enter control knob B.

Knob B

The { is the OFF position preventing gas entering the main burner if the pilot is lit. The knob should be turned slowly anticlockwise. This allows gas to enter the burner and be ignited by the pilot flame. Once ignition has taken place, the fire may be set to any level between min. and max. by adjusting the control knob B.

10.2 To light

1.Push in and turn the control knob (A) from { anticlockwise to the setting Knob A (small flame). You will hear a ignition click. Check that the pilot is lit (if not repeat).

2.Continue to hold in the control knob for a further ten seconds to ensure that the pilot flame is stable.

3.Release the knob. The pilot should remain alight.

4.Turn the control knob A to the Knob B position.

5.Turn knob B slowly anticlockwise, the fire should then ignite.

6.Adjust flames to the required level.