Faber CADRA NOVA Uk/Irl, Feeling, Silence, Whisper, Cadra, Misty, Nova, Spectra, Shelf dimensions

Models: CADRA NOVA MISTY FEELING SILENCE SPECTRA NOVA WHISPER

1 29
Download 29 pages 61.36 Kb
Page 5
Image 5
UK/IRL

UK/IRL

 

 

 

UK/IRL

C

A

E

D3.1 Builders opening and surround (continuing)

B

F

G

FeelingK

IL M

JH

fig. 1

3.1 Builders opening and surround (continuing)

If the builders' opening is constructed out of non-combustible composition board (Fibrelux) and you install the appliance without a mantel then:

-Ventilate the space above the appliance (min. 1000 mm2 ).

-Always fit the DC convection set.

-The plaster of the outside has to be resistant to a high temperature. Use therefore the plaster materials especially made for this, to prevent discoloring (min. 100 °C temperature resistant).

 

Builders opening (mm)

Feeling

Silence

Whisper

Spectra

Cadra

Misty

 

 

 

 

 

Nova

Nova

 

A

Opening width*

960

960

780

780

680

710

B

Opening height*

649

649

705

698

798

890

C

Opening depth*

385

385

430

430

430

370

 

Shelf dimensions

 

 

 

 

 

 

 

(combustible)

 

 

 

 

 

 

D

Min. height shelf from

 

 

 

 

 

 

 

top frame

350

350

350

350

350

350

E

Depth shelf max.

150

150

150

150

150

150

 

Dimensions (mm)

 

 

 

 

 

 

F

Box width

880

880

750

750

650

698

G

Box depth

366

366

397

375

375

338

H

Box height

636

636

714

715

815

879

I

Frame width

1064

1064

815

794

694

740

J

Frame height

678

678

720

703

803

905

K

Frame thickness

47

20

16

30

30

144

L

Position flue

 

 

 

 

 

 

 

(behind frame)

255

255

257

235

235

196

M

Position flue (from the

 

 

 

 

 

 

 

back side box)

111

111

140

140

140

142

 

 

 

 

 

 

 

 

*the points A until C applies a tolerance from:

 

– 0 mm and + 5 mm.

table 1

 

If the appliance is to be fitted against a wall with combustible cladding, the cladding must be removed from the area covered by the surround.

The minimum height from the top surface of the fire to the underside of any shelf made from wood or other combustible materials is as follows:

-For a shelf up to 150 mm deep – Minimum height = 350 mm (fig. 1).

-If the shelf depth is greater than 150 mm add 50 mm to the upper- clearance height for every 25 mm increase in shelf depth.

-Side clearance = Minimum distance from the side of the fire frame to combustible material = 150 mm.

6

 

 

 

7

 

 

Page 5
Image 5
Faber CADRA NOVA Uk/Irl, Feeling, Silence, Whisper, Cadra, Misty, Nova, Builders opening and surround continuing, Spectra