Appendix A. Data Tables

Appendix A.1. Data Table 1: Array Locations of ‘Everything’

In the following table the array location indicates the offset in the Data Array at which a data field can be found. (This offset is relative to the offset specified in the Map Descriptor) The columns headed 2, 3 … indicate the unit types for which the data fields are available. For example: The field ‘d_temp’ can be read from unit types 2, 5,6,7,9 but not from any of the other unit types. It is beyond the scope of this manual to describe each field and to indicate valid ranges. Such information should be obtained from the Data Aire Corporation.

‘x’ Indicates Read only

‘X’ Indicates a point that can be read & written. ‘w’ Indicates a write only point.

Array

Method

Num

Data Field

2

3

4

5

6

7

8

9

14

15

Message Type

Location

Elements

 

 

 

 

 

 

 

 

 

 

 

 

 

1

1

1

Zone

 

w

w

w

w

w

w

w

w

w

Dap-Config

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

1

1

Inhibit

 

w

w

w

w

w

w

w

w

w

Dap-Config

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

4

1

unitType

x

x

x

x

x

x

x

x

x

x

Dap-Unit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

2

1

temp

x

 

 

x

x

x

 

x

 

 

Dap-Stat

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

2

1

hum

x

 

 

x

x

x

 

x

 

 

Dap-Stat

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

2

1

d_temp

x

 

 

x

x

x

 

x

 

 

Dap-Stat

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

3

8

mode

x

 

 

x

x

x

 

x

 

 

Dap-Stat

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

23

3

8

hold

x

 

 

x

x

x

 

x

 

 

Dap-Stat

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

39

1

1

cs_on

x

 

 

x

x

x

 

x

 

 

Dap-Stat

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40

1

1

hs_on

x

 

 

x

x

x

 

x

 

 

Dap-Stat

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

41

1

1

valvePCT

x

 

 

x

x

x

 

x

 

 

Dap-Stat

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

42

1

1

hVlvPCT

x

 

 

x

x

x

 

x

 

 

Dap-Stat

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

43

4

14

Errors - see Appendix E.4

x

 

 

x

x

x

 

x

 

 

Dap-Stat

 

 

 

for more information

 

 

 

 

 

 

 

 

 

 

 

57

2

1

hiTemp

x

 

 

x

x

x

 

x

 

 

Dap-Stat

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

58

2

1

loTemp

x

 

 

x

x

x

 

x

 

 

Dap-Stat

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

59

2

1

hiHum

x

 

 

x

x

x

 

x

 

 

Dap-Stat

60

2

1

loHum

x

 

 

x

x

x

 

x

 

 

Dap-Stat

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

61

1

1

chilled_water

x

 

 

x

x

x

 

x

 

 

Dap-Stat

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

62

1

1

compressor_config

x

 

 

x

x

x

 

x

 

 

Dap-Stat

63

1

1

heat_strip_config

x

 

 

x

x

x

 

x

 

 

Dap-Stat

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

64

1

1

hum_config

x

 

 

x

x

x

 

x

 

 

Dap-Stat

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

65

1

1

csUtilPct

x

 

 

x

x

x

 

x

 

 

Dap-Stat

66

1

1

hsUtilPct

x

 

 

x

x

x

 

x

 

 

Dap-Stat

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

67

1

1

valveUtilPct

x

 

 

x

x

x

 

x

 

 

Dap-Stat

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

68

1

1

humUtilPCT

x

 

 

x

x

x

 

x

 

 

Dap-Stat

69

1

1

alrm_select_1

x

 

 

x

x

x

 

x

 

 

Dap-Stat

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

70

1

1

alrm_select_2

x

 

 

x

x

x

 

x

 

 

Dap-Stat

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

71

1

1

alrm_select_3

x

 

 

x

x

x

 

x

 

 

Dap-Stat

72

1

1

alrm_select_4

x

 

 

x

x

x

 

x

 

 

Dap-Stat

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 