6HFXULW\&RGHV$XWKRULW\/HYHOV&RQW
+RZWR$VVLJQ8VHU&RGHVDQG$WWULEXWHV
The following lists the various command strings for adding user codes and attributes.
Refer to the User Setup chart at the back of this manual for factory assignments of user attributes and to keep a record of user programming.
Add User Code:
Delete User Code:
System Master code + [8] + user no. + new user’s code
User 01 | = installer | User |
User 02 | = master | (factory set master code is 1234) |
The Keypad beeps once to confirm that new user was added. System Master code + [8] + [user no.] + [#] [0]
Authority Level:
Factory Assignments: users
Access Group:
Factory Assignments: none
RF User Number:
Factory Assignments: none
Pager On/Off:
Factory Assignments: users
The user code and all attributes programmed for this user number, including any associated RF keys, are erased from the system.
System Master code + [8] + [user no.] + [#] [1]+ auth. level
Authority Levels (see definitions on previous page):
0 | = standard user | 2 | = guest |
1 | = arm only | 3 | = duress |
System Master Code + [8] + [user no.] + [#] [2]+ group
You can assign users to a group, then set an access schedule that defines the times this group of users can operate the system. The system ignores these users outside the scheduled times.
System Master Code + [8] + [user no.] + [#] [4]+ zone no.
Use this command to assign a wireless button device (keyfob) to this user (keyfob must be enrolled in system first; see installer).
Zone number: enter the zone number assigned to a button on the keyfob that will be used for arming/disarming by this user.
System Master Code + [8] + [user no.] + [#] [5] + 0 or 1
You can program a user so that a message is sent to a pager whenever this code is used to arm or disarm the system. Paging On/Off: 1 = allow paging; 0 = no paging for this user
– 31 –