US
CA (EN)
14Installation instructions
Converting to a different gas type
Changing the injectors
The cooktop is set to NG. A conversion kit to LP is supplied with the cooktop.
To change the injectors, you will need a 9⁄32” (7 mm) box spanner (and a 13⁄32” (10 mm) ring spanner for CG365D models).
1Turn off the cooktop and disconnect from the power supply.
Important! | Fig.1 |
Disconnect cooktop from the power supply before continuing.
2 Make sure all gas valves are turned off.
3 Remove all grates and burner parts.
4 Unscrew the injectors (save for future use) and replace them with the correct ones (size numbers are stamped on the side, eg 70= 0.70 mm). See Fig. 1.
CG365D wok burner only
venturi
5 Remove the 2 screws holding each burner bowl (3 on the wok burner).
6 Lift hob tray from the product.
| Important! |
| Fig.2 |
| Beware of sharp edges. |
| |
| lifting off | yellow tip | |
7 | Replace the wok injector with the correct | ||
| one using a 13⁄32” (10 mm) ring spanner. |
|
|
8 | Reset the venturi (see Fig. 2): |
|
|
| With the product isolated from the |
|
|
| electrical supply, ignite the burner using a |
|
|
| match. The flame will probably be lifting |
|
|
| off the burner (see Fig. 3). |
|
|
| Loosen the venturi securing screw. Move | Fig.3 | Fig.4 |
| the venturi towards the injector until the | ||
|
|
| |
| flame begins to ‘yellow tip’ (see Fig. 4). |
|
|
| Move the venturi back until the ‘yellow tip’ |
|
|
| just disappears (see Fig. |
|
|
| correct venturi setting. Tighten the | good flame |
|
| securing screw. |
| |
|
|
|
9To refit the hob tray, repeat steps 5 & 6 in
reverse.
10Reset the minimum setting (see ‘Minimum
setting or | Fig.5 |
11After reassembly, verify the insulation resistance and ground continuity of the electrical circuit.
12The label supplied with the injectors should be placed over the existing gas type label to indicate the change.