Fisher & Paykel CG365D, CG365C 14Installation instructions, Converting to a different gas type

Models: CG365C CG365D

1 60
Download 60 pages 58.11 Kb
Page 16
Image 16
14Installation instructions

US

CA (EN)

14Installation instructions

Converting to a different gas type

Changing the injectors

The cooktop is set to NG. A conversion kit to LP is supplied with the cooktop.

To change the injectors, you will need a 9⁄32” (7 mm) box spanner (and a 13⁄32” (10 mm) ring spanner for CG365D models).

1Turn off the cooktop and disconnect from the power supply.

Important!

Fig.1

Disconnect cooktop from the power supply before continuing.

2 Make sure all gas valves are turned off.

3 Remove all grates and burner parts.

4 Unscrew the injectors (save for future use) and replace them with the correct ones (size numbers are stamped on the side, eg 70= 0.70 mm). See Fig. 1.

CG365D wok burner only

venturi

5 Remove the 2 screws holding each burner bowl (3 on the wok burner).

6 Lift hob tray from the product.

 

Important!

 

Fig.2

 

Beware of sharp edges.

 

 

lifting off

yellow tip

7

Replace the wok injector with the correct

 

one using a 13⁄32” (10 mm) ring spanner.

 

 

8

Reset the venturi (see Fig. 2):

 

 

 

With the product isolated from the

 

 

 

electrical supply, ignite the burner using a

 

 

 

match. The flame will probably be lifting

 

 

 

off the burner (see Fig. 3).

 

 

 

Loosen the venturi securing screw. Move

Fig.3

Fig.4

 

the venturi towards the injector until the

 

 

 

 

flame begins to ‘yellow tip’ (see Fig. 4).

 

 

 

Move the venturi back until the ‘yellow tip’

 

 

 

just disappears (see Fig. 5)this is the

 

 

 

correct venturi setting. Tighten the

good flame

 

 

securing screw.

 

 

 

 

9To refit the hob tray, repeat steps 5 & 6 in

reverse.

10Reset the minimum setting (see ‘Minimum

setting or turn-down’).

Fig.5

11After reassembly, verify the insulation resistance and ground continuity of the electrical circuit.

12The label supplied with the injectors should be placed over the existing gas type label to indicate the change.

Page 16
Image 16
Fisher & Paykel CG365D, CG365C 14Installation instructions, Converting to a different gas type, Changing the injectors