Installation instructions 15
Leak testing
Leak testing of the appliance shall be conducted according to the manufacturer’s instructions.
The appliance and its individual
The appliance must be isolated from the gas supply piping system by closing its individual manual
Maximum inlet gas supply pressure 20” W.C. (5 kPa)
Minimum gas supply pressure for regulator testing 5” W.C. Natural Gas, 12” W.C. LP Gas.
After installing the gas supply and making all connections, check thoroughly for possible leaks:
1Turn all control dials on unit to “off” position.
2 Open the valve on the gas supply.
3 Using a leak detection fluid (eg Rocol leak detection spray), check each gas connection one at a time by brushing the solution over the connection. The presence of bubbles will indicate a leak.
4 If necessary, tighten the fitting and recheck for leaks.
5 Turn on burner valve and light each burner.
6 Check for a clear blue flame without yellow tipping. If burners show any abnormalities, check that they are located properly and in line with the injector orifice.
Minimum setting or turn-down
After installation check the minimum setting. This has been preset at the factory for NG but needs to be checked and then reset if necessary. To adjust for minimum setting (if applicable), you will need a Ø 7⁄64 “ x 1 ¾” (Ø 2.5 x 45 mm) screwdriver.
(A suitable screwdriver is available as Fisher & Paykel spare part FB200467).
1Ignite the burner and set the dial to its minimum position.
2 Remove the dials.
3 Rotate the
4 When the setting is right, check regulation by quickly
rotating the dial from the maximum to the minimum delivery position. The flame must not go out and the
US
CA (EN)
Fig.6 Minimum setting adjustment