How to Set the Temperature

1.If the water heater is off, press the ON/OFF button to turn on.

2.Press the “Priority button” on the

temperature controller. The green Priority light will glow indicating that this controller is controlling the temperature and that the Rinnai water heater is ready to supply hot water.

The priority can only be changed while no hot water is running.

3.Press the ▲ or ▼ buttons to obtain the desired temperature setting.

All hot water sources are able to provide water at this temperature setting until it is changed again at this or another temperature controller.

Temperature Controller Settings

This water heater will attempt to provide hot water at the temperature setting even when the water flow is varied or when more than 1 tap is in use. The water heater can deliver water at only one temperature setting at a time. The available temperatures for a given model are provided below.

Model

 

 

 

 

Temperature Settings Available (ºF)

 

 

 

 

RL75i

98

100

102

104

106

108

110

115

120

125

130

135

140

150

160

 

 

 

 

 

 

 

 

 

 

 

*

*

*

*

**

**

 

RL94i

98

100

102

104

106

108

110

115

120

125

130

135

140

150

160

185

 

 

 

 

 

 

 

 

 

 

*

*

*

*

**

**

**

R98LSi

98

100

102

104

106

108

110

115

120

125

130

135

140

150

160

185

R98LSi-ASME

 

 

 

 

 

 

 

 

 

 

 

 

 

**

**

**

Temp in Celsius ºC

37

38

39

40

41

42

43

46

49

52

54

57

60

66

71

85

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

An older controller, MC-45, can be installed with the RL75i and RL94i by moving switch No. 6 in the bank of 6 switches to ON. Some of the temperature settings will be slightly different from the above table.

VB Series Indoor LS Manual

7

Page 7
Image 7
Rinnai RL75I, RL94I How to Set the Temperature, Temperature Controller Settings, Model Temperature Settings Available ºF