Specifications

Specifications

Model

 

RL75i

RL94i

 

R98LSi

 

R98LSi-ASME

 

 

 

 

 

 

 

 

 

Minimum Gas Consumption Btu/h

9,900 (NG)

 

 

19,000

 

10,300 (LPG)

 

 

 

 

 

 

 

 

 

 

Maximum Gas Consumption Btu/h

180,000

199,000 (NG)

 

 

237,000

 

190,000 (LP)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Hot water capacity (Min - Max) *

0.4 - 7.5 GPM

0.4 - 9.4 GPM

 

0.6 - 9.8 GPM

 

(1.5 - 28.5 L/min)

(1.5 - 35.5 L/min)

 

(2.4 - 37 L/min)

 

 

 

Hot water capacity (45°F rise)

6.6 GPM

7.1 GPM

 

 

8.5 GPM

 

(25.0 L/min)

(27.0 L/min)

 

(32.2 L/min)

 

 

 

 

 

 

 

 

 

 

 

 

 

Default Temperature Setting (no controller)

 

120º F (49º C)

 

 

 

Temperature Controller Default Setting

 

104º F (40º C)

 

 

 

 

 

 

 

 

 

 

 

Maximum Temp Setting (commercial **)

160º F (71º C)

 

 

185º F (85º C)

 

Maximum Temp Setting (residential)

Selectable at 120º F (49º C) or at 140º F

 

140º F (60º C)

see Temperature Ranges for more information

(60º C)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Minimum Temperature Setting

 

98º F (37º C)

 

 

 

Weight

 

51 lb (23 kg)

53 lb (24 kg)

 

55 lb (25 kg)

 

Efficiency

 

Energy Factor: 0.82

 

Thermal Efficiency:

84.0%

Noise level

 

 

49 dB

 

 

 

 

 

Normal

76 W

83 W

 

 

99 W

 

Electrical Consumption

Standby

 

2 W

 

 

 

 

 

Anti-frost Protection

184 W

 

 

116 W

 

By-Pass Control

 

Fixed

 

 

Electronic

 

 

 

Minimum Gas Supply

Natural Gas

 

5.0 inch W.C.

 

 

 

Pressure

Propane

 

8.0 inch W.C.

 

 

 

Maximum Gas Supply

Natural Gas

 

10.5 inch W.C.

 

 

 

Pressure

Propane

 

13.5 inch W.C.

 

 

 

Type of Appliance

 

Direct Vent, Temperature controlled continuous flow gas hot water system.

Operation

 

With or without remote controls, mounted in kitchen, bathroom, etc.

Approved Gas Type

 

Natural Gas or Propane - Ensure unit matches gas type supplied at the installation

Connections

 

Gas Supply: 3/4" MNPT, Cold Water Inlet: 3/4" MNPT, Hot Water Outlet: 3/4" MNPT

Ignition System

 

 

Direct Electronic Ignition

 

 

 

Electric Connections

 

Appliance: AC 120 Volts, 60Hz. Remote Control: DC 12 Volts (Digital)

 

 

 

 

 

 

 

Water Temperature Control

 

Simulation Feedforward and Feedback.

 

Water Supply Pressure

 

Minimum Water Pressure: 20 PSI (Recommended 30-80 PSI for maximum

 

 

 

 

 

 

 

 

Maximum Water Supply Pressure

 

150 PSI

 

 

 

Remote Control Cable

 

Non-Polarized Two Core Cable (Minimum 22 AWG)

 

 

 

 

 

 

 

 

Energy Star Qualified

 

Yes

Yes

 

No (not applicable)

 

 

 

 

 

 

 

 

 

Certified for installation in manufactured (mobile)

Yes

Yes

 

No

 

 

No

homes

 

 

 

 

 

 

 

 

 

 

 

 

*Minimum flow may vary slightly depending on the temperature setting and the inlet water temperature.

**for commercial and hydronic applications requiring higher temperatures

Rinnai is continually updating and improving products. Therefore, specifications are subject to change without prior notice.

The maximum inlet gas pressure must not exceed the value specified by the manufacturer. The minimum value listed is for the purpose of input adjustment.

VB Series Indoor LS Manual

3

Page 3
Image 3
Rinnai RL75I, RL94I installation manual Specifications, RL75i, RL94i, R98LSi-ASME