Using the Water Smart / Bath Fill Function

Overview

This function is exclusive to the BC-100V temperature controller. The bath fill function allows the consumer to fill a tub with a preset volume of water at a preset temperature. This is done by pressing the bath fill button on the BC-100V controller while no hot water is flowing and then opening only the hot water tap. The water heater will stop the hot water flow when the preset volume has been reached. The hot water tap should then be closed and the bath fill button pressed.

The temperature settings for the bath fill function are limited to those in the table below.

Bath Fill Temperature Settings

Available

ºF 98 100 102 104 106 108

ºC 37 38 39 40 41 42

ºF 110 112 114 116 118 120

ºC 43 44 46 47 48 49

Setting the Water Volume

The default volume is set to 25 gallons. The volume can be set between 10 and 120 gallons.

1. Press the “Priority” button on the temperature controller. The green Priority light will glow indicating that this controller is controlling the temperature and that the Rinnai water heater is ready to supply hot water.

2. Press the “Water Smart Bath Fill” button to set the water volume and temperature.

3. Press the “Temp” ▲ or ▼ buttons to obtain the desired temperature setting.

4.Press the “Water Vol.”▲ or ▼ buttons to obtain the desired water volume in gallons.

5.Press the “Water Smart Bath Fill” button.

VB Series Indoor LS Manual

9

Page 9
Image 9
Rinnai RL75I, RL94I installation manual Using the Water Smart / Bath Fill Function, Overview, Setting the Water Volume