Rinnai RL75I Clearances from Appliance, Attachment of the Water Heater, to top, to side, to front

Models: RL75I RL94I

1 72
Download 72 pages 60.55 Kb
Page 17
Image 17
Clearances from Appliance

Clearances from Appliance

 

to Combustibles

to Non-

 

 

 

to top

 

 

 

 

 

 

 

 

 

 

 

 

Combustibles

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RL75i

R98LSi

RL75i

R98LSi

 

 

 

 

 

 

 

RL94i

RL94i

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Top of

6 inches **

12 inches

2 inches **

2 inches

 

 

 

 

 

 

Heater

(152 mm)

(305 mm)

(51 mm)

(51 mm)

to side

 

 

 

 

 

 

 

 

 

 

 

 

 

Back of

0 (zero)

0 (zero)

0 (zero)

0 (zero)

 

 

 

 

 

 

Heater

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Front of

6 inches

6 inches

6 inches

6 inches

 

 

 

 

 

 

Heater

(152 mm)

(152 mm)

(152 mm)

(152 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sides of

2 inches

2 inches

1/2 inch

1/2 inch

 

 

 

 

 

 

 

 

 

 

 

 

Heater

(51 mm)

(51 mm)

(13 mm)

(13 mm)

 

 

 

 

to front

 

 

 

 

 

 

 

 

 

 

 

 

 

Ground/

12 inches

12 inches

12 inches

2 inches

 

 

 

 

Bottom

(305 mm)

(305 mm)

(305 mm)

(51 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Vent

0 (zero)

4 inches *

0 (zero)

0 (zero)

 

 

 

 

 

 

 

to ground/bottom

 

 

 

 

 

 

 

 

 

 

*4 inches (102 mm) for enclosed area; 1 inch (26 mm) for unenclosed area.

**0 inches from vent components and condensate drain line.

The clearance for servicing is 24 inches in front of the water heater.

For closet installation: clearance is 6 inches (152 mm) from the front.

Attachment of the Water Heater

1.Identify the installation location and confirm that the installation will meet all required clearances.

2.Securely attach the water heater to the wall using any of the holes in the wall installation brackets which are at the top and bottom of the water heater. Ensure that the attachment strength is sufficient to support the weight. Refer to the weight of the water heater in the Specifications section.

NOTE: Rinnai water heaters should be installed in an upright position. Do not install upside down or on its side.

wall installation

brackets

VB Series Indoor LS Manual

17

Page 17
Image 17
Rinnai RL75I, RL94I Clearances from Appliance, Attachment of the Water Heater, to top, to side, to front, to ground/bottom