Fisher & Paykel CG365D 16Installation instructions, Checking the gas type, Burners, NG Orifice

Models: CG365C CG365D

1 60
Download 60 pages 58.11 Kb
Page 18
Image 18
16Installation instructions

US

CA (EN)

16Installation instructions

Checking the gas type

Burners

NG Orifice

NG

LP Orifice

LP

 

 

(mm)

BTU (MJ/h) @

(mm)

BTU (MJ/h) @

 

 

0.15 psi (4” W.C.)

 

0.41psi (11” W.C.)

RH Rear (Rapid)

1.3 mm

8,000 (8.4 MJ/h)

0.8 mm

8,200 (8.7 MJ/h)

 

 

 

 

 

LH Rear (Semi-rapid)

1.1 mm

5,800 (6.1 MJ/h)

0.7 mm

5,700 (6.0 MJ/h)

 

 

 

 

 

RH Front (Auxillary)

0.85 mm

3,000 (3.2 MJ/h)

0.55 mm

3,500 (3.7 MJ/h)

 

 

 

 

 

LH Front (Rapid)

1.3 mm

8,000 (8.4 MJ/h)

0.8 mm

8,200 (8.7 MJ/h)

 

 

 

 

 

 

CG365C Center (Wok)

1.75 mm

14,000 (14.8 MJ/h)

1.05 mm

13,000

(13.7 MJ/h)

 

 

 

 

 

 

CG365D Center (Wok)

2.15 mm

20,000 (21.1 MJ/h)

1.22 mm

19,000

(20 MJ/h)

 

 

 

 

 

 

Clamping down the cooktop

Place the cooktop into the cutout and tighten it

with the supplied clamps. These will cope with the countertop thicknesses ¾”- 2” (19 - 50 mm) when used in the two orientations shown.

Do not over tighten.

3/4” - 2”

(19 mm - 50 mm)

Dirty ignitors?

Injectors incorrect or blocked?

Power supply polarity/grounding OK?

Supply voltage OK?

Draft/extraction? (advise the customer)