US
part number 526608 J 06/2004 (page 1 of 6)R
| (NOTE: FOR SINGLE | R MODELS, REFER TO BACK OF THIS BOOK) |
PLEASE NOTE: Your model of | R may differ from the model shown in the diagrams. Diagrams have been simplified to enable clearer instruction. |
FOLLOW THESE INSTRUCTIONS BEFORE REFERRING TO PRODUCT INSTALLATION INSTRUCTION SHEET P/N 526607.
BEFORE YOU START
of the R can be made to match your kitchen cabinetry. This diagram, with the addition of your own measurements will help you calculate the required panel sizes.
CABINETRY ALIGNMENT
The following calculations assume:The top of the Upper Panel is to be aligned with the top of the adjacent cabinetry. The final panel/cabinetry alignment is achieved by adjusting the R ’s feet
open |
WIDTH OF ALL PANELS
Measure the width between adjacent door/drawer fronts and write it in the first box below, then complete the equation. For example:
241/4” (616mm) |
|
| 2 x | 3/32” (2.5mm) |
|
|
| 241/16” (611mm) |
|
| |||||||
|
| |||||||
|
|
|
| door clearance |
|
| width of all panels |
2x
|
|
|
|
|
|
| door clearance |
|
| width of all panels | |||||||||
|
|
|
|
|
| (3/32” (2.5mm) MIN) | (23 7/16” (595mm) MIN) | ||||||||||||
HEIGHT OF UPPER PANEL |
|
|
|
|
|
| |||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
For example: | 155/8” (398mm) |
|
|
|
|
| 0mm |
|
|
|
|
| 155/8” (398mm) |
| |||||
|
|
|
|
|
|
|
|
|
|
| |||||||||
| standard height |
|
|
|
| door extension |
|
|
| height of upper panel | |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
155/8 (398mm) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
standard height |
|
| door extension |
|
| height of upper panel | |||||||||||||
|
|
|
|
|
| (0” recommended) |
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
HEIGHT OF LOWER PANEL
Measure door/drawer height (or equivalent) and write it in the first box below, then complete the equation. For example:
30” (762mm) 155/8” (398mm) 5/16” (8mm) 141/16” (356mm)
|
| height of upper panel | air gap |
| height of lower panel | |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 5/16 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| (8mm) |
|
|
|
|
MIN 281/4” (717.5mm) + |
|
|
|
|
|
|
|
|
|
| ||
|
| height of upper panel | gap between |
| height of lower panel | |||||||
|
|
|
|
|
|
|
| panels | (1217/64” (311.5mm) MIN) | |||
|
|
|
|
|
|
|
|
|
|
|
|
|
to be above the R where required.
Important!
The air vent between the Upper and Lower Panels must not be covered. An air gap of 5/16” (8mm) MUST be provided.