Fisher & Paykel DD603I Grounding The Mounting Brackets, Connecting The Badge Wires

Models: DD603I

1 12
Download 12 pages 41.18 Kb
Page 11
Image 11
STEP 5: GROUNDING THE MOUNTING BRACKETS

PANEL PREPARATION INSTRUCTIONS

STEP 5: GROUNDING THE MOUNTING BRACKETS

STEP 6: CONNECTING THE BADGE WIRES WARNING!

Be sure the Product is not plugged in.

Plug the green Badge grounding wire onto a Mounting Bracket tab. Plug the grounding wire from the Product onto the other Mounting Bracket tab.

Connect the Badge plug to the top of the Badge Isolator Box. WARNING!

The mounting bracket MUST be grounded.

STEP 6: CONNECTING THE BADGE WIRES

Manual background WARNING!

Be sure the Product is not plugged in.

Important!

The Badge Isolator Board is an electrostatic sensitive device. Be sure you are adequately grounded when connecting or disconnecting the Badge by wearing an grounding strap or by grounding yourself to the Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background.

Connect the Badge plug to the top of the Badge Isolator Box.

5

Page 11
Image 11
Fisher & Paykel DD603I Grounding The Mounting Brackets, Connecting The Badge Wires, Panel Preparation Instructions