FOCUS Enhancements MANL-1023-08 manual TC DROP, NON-DROP Ntsc only, TC NON-DROPGroup Default

Models: MANL-1023-08

1 154
Download 154 pages 29.49 Kb
Page 82
Image 82

FS-100 Functions

TC DROP, NON-DROP NTSC only

These parameters are only available for NTSC and only one may be enabled at a time. Drop and non-drop enable and disable the drop-frame function that modifies how the timecode is calculated during recording.

TC DROP

Enables the drop-frame function:

Frames 00 and 01 are dropped from each minute of video recorded.

Exception - The first minute of each hour is not dropped.

TC NON-DROPGroup Default

Disables drop-frame. No frames are dropped during recording and the timecode reflects the actual time during recording.

Use with TC FREE RUN or TC REGEN

TC DROP and TC NON-DROP may only be set when using the TC FREE RUN or TC REGEN settings.

Type of Seperator Indicates TC DROP or NON-DROP

The timecode displayed on the LCD indicates the TC DROP/NON-DROP mode by using either a semi-colon or a colon as a separator between hours, minutes, seconds and frames:

DROP

HH;MM;SS;FF

NON-DROP

HH:MM:SS:FF

FS-100 Portable DTE Recorder 64

Page 82
Image 82
FOCUS Enhancements MANL-1023-08 TC DROP, NON-DROP Ntsc only, TC NON-DROPGroup Default, Use with TC Free RUN or TC Regen