Hardware installation

Changing FortiGate-5001FA2 jumper settings

You can install the following types of SFP transceivers for connectors 1, 2, 3, and 4:

optical SFP transceivers

SFP 1000Base-LX, SM module

SFP 1000Base-SX, MM module (multimode)

copper SFP transceivers

SFP 1000Base-T, SERDES version only (SGMII version not supported)

To install SFP transceivers

To complete this procedure, you need:

A FortiGate-5001FA2 board

Four SFP transceivers

An electrostatic discharge (ESD) preventive wrist strap with connection cord

Caution: FortiGate-5001FA2 boards must be protected from static discharge and physical ! shock. Only handle or work with FortiGate-5001FA2 boards at a static-free workstation.

Always wear a grounded electrostatic discharge (ESD) preventive wrist strap when handling FortiGate-5001FA2 boards.

1 Attach the ESD wrist strap to your wrist and to an ESD socket or to a bare metal surface on the chassis or frame.

2 Remove the caps from SFP cage sockets on the FortiGate-5001FA2 front panel.

Caution: Handling the SFP transceivers by holding the release Latch can damage the

! connector. Do not force the SFP transceivers into the cage slots. If the transceiver does not easily slide in and click into place, it may not be aligned correctly. If this happens, remove the SFP transceiver, realign it and slide it in again.

3For cage slots 1 and 2, hold the sides of the SFP transceiver and slide SFP transceiver into the cage socket until it clicks into place.

4For cage slots 3 to 8, turn each SFP transceiver over before sliding it into the cage slot until it locks into place.

Changing FortiGate-5001FA2 jumper settings

The JP3 jumper on the FortiGate-5001FA2 board is factory set by Fortinet into one of two positions (see Figure 3 on page 12):

For a FortiGate-5140 or FortiGate-5050 chassis, the jumper connects pins 2 and 3

For a FortiGate-5020 chassis, the jumper connects pins 1 and 2

The jumper must connect pins 2 and 3 if the chassis contains a shelf manager. Both the FortiGate-5140 and the FortiGate-5050 contain shelf managers, and the FortiGate-5020 does not.

If the JP3 jumper settings are incorrect, when you insert the FortiGate-5001FA2 board into a chassis the board may not start up or may not be able to communicate with the chassis shelf manager.

FortiGate-5001FA2 Security System Guide

 

01-30000-0379-20080606

11

Page 11
Image 11
Fortinet manual Changing FortiGate-5001FA2 jumper settings, To install SFP transceivers