Foster S4000 manual Summary Of The Faults, Before Calling For Service, Problem, Possible Causes

Models: S4000

1 31
Download 31 pages 51.51 Kb
Page 23
Image 23
EN 13/ IF OPERATING ANOMALIES OCCUR

EN 13/ IF OPERATING ANOMALIES OCCUR

• SUMMARY OF THE FAULTS

d01: water supply fault (tap)

d07: overflow / anti-leak fault

 

 

d02: draining fault

d08: sprinkling distribution fault

 

 

d03: heating fault

d11: pressure sensor fault

 

 

d04: temperature fault

d12: filling fault (water inlet detection system)

 

 

d05: fault – motor under load

d13: overheating fault

 

 

d06: fault - motor overload

d14 : installation fault : (incorrect drainage

connection or inadequate flow rate and tap).

 

 

 

Tip:

If one of the above faults occurs and you need to call a repair man, remember to tell him the message displayed (d01, d02..) as this information will help him.

• BEFORE CALLING FOR SERVICE

Problem

Possible Causes

What to do?

 

 

 

The door falls heavily when

- Door springs not tensioned

- Tighten the two tensioning

opened (integratable model)

enough to compensate for the

screws accessible in the bot-

 

weight of the panel.

tom section above the front

 

 

feet.

 

 

 

The door does not stay horizontal

- Door springs tensioned too

- Loosen the two tensioning

when open or returns too quickly

much.

screws accessible in the bot-

(integratable model)

 

tom section above the front

 

 

feet.

 

- No wooden panel.

- Fit a temporary wooden panel

 

 

on the appliance and adjust

 

 

the springs.

 

 

 

The door catches when closing

- Appliance not stable

- Adjust the feet.

 

- Door not centred on the tub

- Re-centre by adjusting the

 

 

rear feet.

 

 

 

The upper basket does not stay

- Poor manipulation (the basket

- Act more progressively (see

in the high position

is being pulled upwards too

instructions), one side and

 

quickly)

then the other.

 

 

 

Small leak around or under the

- Leak from the tap.

- Check that a seal is fitted and

appliance (move the appliance

- Leak from the appliance.

retighten the nut.

to locate the leak)

- Close the water tap and call a

 

(Cf. table fault d07).

technician.

 

 

 

 

 

Small leak at the door

- Appliance not stable or not level

- Adjust the feet.

 

- Door not centred on the tub.

- Re-centre by adjusting the rear

 

 

feet.

 

 

 

52

Page 23
Image 23
Foster S4000 Summary Of The Faults, Before Calling For Service, EN 13/ IF OPERATING ANOMALIES OCCUR, Problem, What to do?