PREVIOUS DOCUMENT
Technical Data
Category II 2H3+ appliance
TYPE OF GAS
G20
natural gas (methane) 20 mbar
liquefied gas
30/37 mbar
BURNER
Small
Medium
Fast
Small
Medium
Fast
INJECTOR MARKING
72
97
115
140
50
65
85
91
RATED THERMAL | REDUCED THER- |
CAPACITY | MAL CAPACITY |
IN WATTS | IN WATTS |
1000 | 400 |
1750 | 440 |
3000 | 800 |
3300 | 1600 |
1000 | 400 |
1750 | 440 |
3000 | 800 |
3300 | 1600 |
|
|
RATED
CONSUMPTION
95l/h
167l/h
286l/h
314l/h
73g/h
127 g/h
218 g/h
240 g/h
E N G L I S H
Overall thermal capacity: see the identification plate on the bottom of the cooktop.
Combustion supporting air: 2 m3/h per kW of installed power - see identification plate.
Supply voltage: 220/230 V 50 Hz
Installation
Installation and connection to the mains should be carried out in compliance with national laws in force.
The following paragraphs describe installation procedures both for the gas and for the electrical sections. These tasks must be performed according to current standards and by qualified personnel: performance by inexpert persons can create dangers. The manu- facturer declines all responsibility for harm to persons or property caused by failure to comply with these requirements.
Important
-The appliance must be installed by expert and qualified personnel according to current standards.
-Turn to a Franke Service Centre for all repairs and maintenance.
-Never use deformed or unstable pots and pans on the burners which could overflow or tip over.
-If the appliance has a cover make sure the burners are cool before closing the cover.
-Close the gas supply valve when the hob is not being used.
The manufacturer accepts no responsibility for injury to persons or damage to property caused by failure to comply with this procedure. This appliance can only be used for cooking. Any tampering with or modification to the appliance can be a source of danger. Make sure gas distribution systems are as required before installing the appliance. The gas for which the hob is designed is indicated on the label on the bottom of the control box. This appliance is not joined to a device for evacuating products of combustion and must be installed and