Always put the proper adhesive label (supplied as an accessory with the nozzles) in the space on the identification plate when transforming the appliance from one type of gas to another. When the appliance operates with LPG (G30 or G31) the adjustment screw must be tightened all the way in. These appliances are supplied as category II 2H3+ devices.

Adjusting minimum

Remove the knobs and turn on the burners and adjust minimum through the hole in the valve shafts using a screwdriver (supplied with the appliance).

Rotate it anti-clockwise so as to increase the minimum. The burner flame must be stable even if the knob is moved suddenly from maximum to minimum.

LOWER MINIMUM

fig. 6

HIGHER MINIMUM

E N G L I S H

Electrical connection

The connection must be made by qualified personnel according to current standards and according to the rules of the trade.

Make sure grid voltage corresponds to the voltage indicated on the identification plate on the bottom of the hob. Make sure the electrical system, meter, fuses, switch, plug and outlet are correctly sized for the current absorption rate of the hob.

Fit a standard plug to the cable and connect it to a suitable power outlet. The yel- low/green cable must be used to make the ground connection.

When installation is terminated the outlet must be accessible in order to be able to disconnect the hob from the electric grid when performing cleaning and maintenance. When the connection is permanent then install a multi-pole switch between the applian- ce and the electric grid. This switch must meet current regulations and have a minimum 3 mm gap between contacts.

The law requires the hob to be connected to an efficient ground system. The cable's ground conductor is coloured yellow/green and must never be interrupted. Make sure the ground system is efficient before making electrical connections.

The manufacturer accepts no responsibility for injury to persons or damage to property caused by failure to comply with this procedure.