Friedrich 2008, 2009 service manual Mechanical Hazard Mechanicalcut/Sever Hazard

Models: 2009 2008

1 60
Download 60 pages 45.7 Kb
Page 52
Image 52
MECHANICAL HAZARD

INSTALLATION INSTRUCTIONS FOR INTERNAL DRAIN KIT (IDK)

Apply Sealer to the bottom of the Drain Plate

Wall Sleeve

Drill a .625” diameter hole here

Sleeve

Base

Dimple

0.5” In

from edge

4.75” From

Drill a .625” back of

diameter basepan hole in the

bottom of the basepan

WARNING

WARNING

MECHANICAL HAZARD

MECHANICALCUT/SEVER HAZARD

Sharp edges and corners. Be careful with

the sharpBe carefuledgeswithandthecornersharp. Wearedgesprotectiveand corners. clothingWearandprotectivegloves, clothingetc. and gloves, etc.

Failure to do so could result in serious injury.

Failure to do so could result in serious injury.

1.DRILL A .625” DIAMETER HOLE IN THE BOTTOM OF THE SLEEVE BASE TO THE DIMENSIONS SHOWN.

2.APPLY A SILICONE TYPE OF SEALER TO THE OUTSIDE BOTTOM EDGES OF THE DRAIN PLATE.

3.INSERT THE DRAIN TUBE INTO THE HOLE AND PRESS THE DRAIN PLATE DOWN TO FORM A WATERTIGHT SEAL AGAINST THE SLEEVE BASE.

4.DRILL A .625” DIAMETER HOLE IN THE BOTTOM OF THE BASE PAN AS SHOWN IN THE ILLUSTRATION. THIS HOLE ALLOWS CONDENSATE TO ENTER THE WALL SLEEVE WHERE IT TRAVELS TO THE DRAIN KIT FOR DISPOSAL.