INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

FOR “WSC” SLEEVE

MOUNTING HARDWARE PROVIDED

ITEM

DESCRIPTION

QTY.

NO.

 

 

1

SCREW, #12A X 2”

5

 

 

 

WALL PREPARATION:

STEP 1 The wall opening required for a “WSC” SLEEVE is 17 1/4” high by 27 1/4” wide.

STEP 2 LINTELS must be used in opening of brick veneer and masonry walls to support the material above the “WSC” SLEEVE. The following considerations should also be given:

A.Adjustable SUB-BASE SB–89 or other unit support must be provided for panel wall type construction and for walls less than 8” thick.

B.A minimum distance of 1” must be allowed on all sides of the unit to adjacent wall and floor. Where the sub–base is required, the minimum distance from the floor to the sleeve must be 3 1/2”. To minimize chances of short cycling of the compressor, the minimum clearance between the ceiling and the top of the unit should be 24”. (See Figure 1).

FIGURE 1

MINIMUM OF 24” REQUIRED FROM TOP OF UNIT TO CEILING.

INSIDE

WALL

MINIMUM OF 1”

SPACING REQUIRED

ON ALL SIDES OF

THE UNIT.

1” MINIMUM 3 1/2” FOR SUBBASE

7/8” MINIMUM

LINTELS

WSC SLEEVE

DRAIN

EXTENSION

9/16” MINIMUM

OUTSIDE WALL