Friedrich 2009, 2008 service manual electrical DATA, Plug/Outlet/Circuit Rating

Models: 2009 2008

1 60
Download 60 pages 45.7 Kb
Page 9
Image 9
electrical DATA

electrical DATA

NOTICEWARNING

ELECTRIC SHOCK HAZARD

Turn off electric power before service or installation.

All electrical connections and wiring MUST be installed by a qualified electrician and conform to the National Electrical Code and all local codes which have jurisdiction.

Failure to do so can result in personal injury or death.

 

 

NOTICE

 

 

 

FIRE HAZARD

 

 

 

Not following the above WARNING could result in fire or

 

 

 

electically unsafe conditions which could cause moderate

 

 

 

or serious property damage.

 

 

 

Read, understand and follow the above warning.

 

 

 

 

 

Wire Size

Use ONLY wiring size recommended for single outlet branch circuit.

Fuse/Circuit Breaker

Use ONLY the correct HACR type and size fuse/circuit breaker. Read electrical ratings on unit’s

 

rating plate. Proper circuit protection is the responsibiity of the homeowner.

Grounding

Unit MUST be grounded from branch circuit through service cord to unit, or through separate

 

ground wire provided on permanently connected units. Be sure that branch circuit or general

 

purpose outlet is grounded.

Receptacle

The field supplied outlet must match plug on service cord and be within reach of service cord.

 

Do NOT alter the service cord or plug. Do NOT use an extension cord. Refer to the table above

 

for proper receptacle and fuse type.

Plug/Outlet/Circuit Rating

 

Circuit Rating

Plug Face

Wall Outlet

Model Numbers

Breaker or T-D Fuse

(NEMA#)

Appearance

 

 

 

 

 

 

 

 

 

 

WS08B10A, WS10B10A,

125V - 15A

5 - 15P

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WS14B10A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WS10B30A, WS13B30A,

250V - 15A

6 - 15P

 

 

 

 

 

 

 

WS16B30A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WE10, WE13, WE16

250V - 20A

6 - 20P

 

 

 

 

 

 

 

WY10, WY13

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The consumer - through the AHAM Room Air Conditioner Certification Program - can be certain that the AHAM Certification Seal accurately states the unit’s cooling and heating capacity rating, the amperes and the energy efficiency ratio.

*HACR: Heating Air Conditioning and Refrigeration

7

Page 9
Image 9
Friedrich 2009, 2008 electrical DATA, Plug/Outlet/Circuit Rating, HACR Heating Air Conditioning and Refrigeration