Models
Power
WallMaster Thru-the-Wall
FRIEDRICH AIR CONDITIONING CO
TECHNICAL SUPPORT CONTACT INFORMATION
Post Office Box 1540 · San Antonio, Texas
4200 N. Pan Am Expressway · San Antonio, Texas
Table Of Contents
IMPORTANT SAFETY INFORMATION
PERSONAL INJURY OR DEATH HAZARDS
ELECTRICAL HAZARDS
MECHANICAL HAZARDS
REFRIGERATION SYSTEM HAZARDS
PROPERTY DAMAGE HAZARDS
INTRODUCTION
FIRE DAMAGE HAZARDS
WATER DAMAGE HAZARDS
SERIAL NUMBER IDENTIFICATION GUIDE
FRIEDRICH wallmaster MODEL NUMBER CODE
W S 08 B 1 0 B
00001
Sleeve / Chassis Dimensions
Specifications
2008 / 2009 PERFORMANCE DATA
ENERGYSTAR models
electrical DATA
Plug/Outlet/Circuit Rating
HACR Heating Air Conditioning and Refrigeration
A. Mechanical components
FUNCTIONAL COMPONENTS
B. Electrical components
C. Hermetic components
To adjust temperature
How to operate the Friedrich WallMaster
To adjust fan speed
To start unit
To set the timer
To Activate Money Saver WY/WE models
Automatic component protection
To adjust temperature
Using the remote control
To adjust fan speed
To set the timer
TESTING THE ELECTRONIC CONTROL
ERROR CODE MODE
ELECTRONIC CONTROL PANEL
Figure 5 “WS” Cooling only models
ERROR CODES LISTING FOR “WS” MODELS
ERROR CODES LISTING FOR “WE/WY” MODELS
REBOOT THE CONTROL PANEL
Figure 8 System Control Switch
SYSTEM CONTROL SWITCH - TEST
Figure 7 System Control Panel
Heat Pump & Electric Heat Models
ELECTRONIC CONTROL OPERATION
COMPONENTS TESTING
Heat Pump w/back up Electric Heat
THERMOSTAT
DEFROST THERMOSTAT
CAPACITORS
DEFROST BULB LOCATION
Capacitor Check with Capacitor Analyzer
DRAIN PAN VALVE
HEATING ELEMENT
Figure 12 Heating Element
Drain Pan Valve
REFRIGERATION SYSTEM SEQUENCE OF OPERATION
Refrigerant Charging
SEALED REFRIGERATION SYSTEM REPAIRS
BURN HAZARD
Method Of Charging / Repairs
FREEZE HAZARD
BURN HAZARD
Overcharged Refrigerant Systems
Undercharged Refrigerant Systems
Restricted Refrigerant System
METERING DEVICE
HERMETIC COMPONENTS CHECK
CHECK VALVE
Capillary Tube Systems
ELECTRIC SHOCK HAZARD
REVERSING VALVE DESCRIPTION/OPERATION
CHECKING THE REVERSING VALVE
TESTING THE COIL
ELECTRIC SHOCK HAZARD
HIGH PRESSURE HAZARD
Touch Test in Heating/Cooling Cycle
Procedure For Changing Reversing Valve
BURN HAZARD
HIGH PRESSURE HAZARD
Single Phase Running and L.R.A. Test
Single Phase Connections
COMPRESSOR CHECKS
Locked Rotor Voltage L.R.V. Test
ELECTRIC SHOCK HAZARD
Single Phase Resistance Test
GROUND TEST
CHECKING COMPRESSOR EFFICIENCY
Recommended procedure for compressor replacement
COMPRESSOR REPLACEMENT
ELECTRIC SHOCK HAZARD
HIGH PRESSURE HAZARD
EXPLOSION HAZARD
EXCESSIVE WEIGHT HAZARD
ROUTINE MAINTENANCE
BLOWER WHEEL / HOUSING / CONDENSER FAN / SHROUD
ELECTRIC SHOCK HAZARD
ROUTINE MAINTENANCE Continued
SLEEVE / DRAIN
FRONT COVER
Problem
Problem
Problem
Possible Cause
Replace fuse, reset breaker. If repeats, check
Overload inoperative. Opens too
Sublimation
HEAT PUMP TROUBLESHOOTING
Incorrect wiring
HEAT PUMP TROUBLESHOOTING
CORRECTIONS
POSSIBLE CAUSES
TEMPERATURE OF VALVE BODY
WARMER THAN VALVE BODY
COOL ONLY MODELS
WALLMASTER WIRING DIAGRAM ELECTRONIC CONTROL
WS08B10A-D,A-F WS10BIOA-D WS14B10A-D
WS14B10A-E WS10B30A-D
COOL WITH ELECTRIC HEAT MODELS
WE10B33C-A WE13B33C-A WE16B33C-A
WALLMASTER WIRING DIAGRAM ELECTRONIC CONTROL
HEAT PUMP WITH ELECTRIC HEAT MODELS
WY10B33C-A WY13B33C-A
WALLMASTER WIRING DIAGRAM ELECTRONIC CONTROL
ELECTROMECHANICAL CONTROL
WALLMASTER WIRING DIAGRAM
WE10B33A-C WE13B33B-D,B-E WE16B33A-C,A-D
COOL WITH ELECTRIC HEAT MODELS
WALLMASTER WIRING DIAGRAM
WY10B33A-C,A-D WY13B33A-C,A-D
ELECTROMECHANICAL CONTROL
HEAT PUMP WITH ELECTRIC HEAT MODELS
Exterior Grilles
Installation Accessories
DK / Drain Kit
SB / Sub Base
MOUNTING HARDWARE PROVIDED
WALL PREPARATION
INSTALLATION INSTRUCTIONS FOR “WSC” SLEEVE
SLEEVE INSTALLATION
INSTALLATION REQUIREMENTS
MECHANICALCUT/SEVER HAHAZARD CUT/SEVER
STEP STEP 3 STEP
MECHANICALCUT/SEVER HAZARD
SIDE PROFILE OF WALL SLEEVE
SEALING GASKET INSTALLATION INSTRUCTIONS
FIGURE A
FIGURE B
MECHANICAL HAZARD MECHANICALCUT/SEVER HAZARD
MECHANICALCUT/SEVER HAZARD
EXCESSIVE WEIGHT HAZARD
MECHANICALCUT/SEVER HAZARD
MECHANICALCUT/SEVER HAZARD
MECHANICALCUT/SEVER HAZARD
SECOND THROUGH FIFTH YEAR
FIRST YEAR
LIMITED WARRANTY
WALLMASTER→ THRU-THE-WALLAIR CONDITIONERS
Page
FRIEDRICH AIR CONDITIONING CO
TECHNICAL SUPPORT CONTACT INFORMATION
Post Office Box 1540 · San Antonio, Texas
4200 N. Pan Am Expressway · San Antonio, Texas
Post Office Box 1540 · San Antonio, Texas
FRIEDRICH AIR CONDITIONING CO