Image 30
ROOM AIR CONDITIONER UNIT

ROOM AIR CONDITIONER UNIT

PERFORMANCE TEST DATA SHEET

DATE: _______________ MODEL:_______________

SERIAL:________________

 

 

 

YES

NO

 

IS THERE A FRIEDRICH SLEEVE INSTALLED?

 

____

____

IS THERE A CHASSIS SEAL GASKET INSTALLED?

____

____

IS MAINTENANCE BEING PERFORMED?

 

____

____

If NO is checked use back of sheet for explanation

 

 

 

ELECTRICAL:

 

 

 

 

 

LINE VOLTAGE (STATIC)

---------

VOLTS

 

 

 

START UP VOLTAGE

---------

VOLTS

 

 

 

AMPERAGE DRAW

---------

AMPS (COOL)

 

 

 

AMPERAGE DRAW

---------

AMPS (HEAT)

 

 

 

COMPRESSOR

 

 

 

 

 

LOCKED ROTOR AMPS

---------

AMPS

 

 

 

RUNNING AMPS

---------

AMPS

 

 

 

LOCKED ROTOR VOLTAGE

---------

VOLTS

 

 

 

INDOOR TEMPERATURES:

 

 

 

 

 

INDOOR AMBIENT TEMPERATURE

 

--------

F

 

RELATIVE HUMIDITY (RH) INDOOR

 

--------

%

 

 

 

 

COOL

 

HEAT

DISCHARGE AIR TEMPERATURE (INDOOR)

----------

F ---------

F

RETURN AIR TEMPERATURE

(INDOOR)

 

----------

F ---------

F

DIFFERENTIAL

 

 

----------

F ---------

F

OUTDOOR TEMPERATURE:

 

 

 

 

 

OUTDOOR AMBIENT TEMPERATURE

 

---------

F

 

RH OUTDOOR

 

 

---------

%

 

CONDENSER:

 

 

 

 

 

DISCHARGE AIR TEMPERATURE (OUTDOOR)

---------

F ----------

F

INTAKE AIR TEMPERATURE (OUTDOOR

 

---------

F ----------

F

DIFFERENTIAL

 

 

---------

F ----------

F

APPLICATION USE -------------------------

ROOM (RESIDENTIAL OR COMMERCIAL)

This is a general guide.

Please consult manual J or M for exact load calculations.

1.If heavily shaded, reduce capacity 10%.

2.If very sunny, add 10%.

3.Add 500 BTU/H per person over 2 people.

4.Add 4,000 BTU/H if area is a kitchen.

Due to variations in room design, climate zone and occupancy, larger areas may require the use of multiple units to provide the optimal cooling solution.