COOLING LOAD ESTIMATE FORM

HEAT GAIN FROM

 

QUANTITY

FACTORS

 

 

BTU/Hr.

 

 

 

 

 

DAY

 

(Quantity x Factor)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No

Inside

Outside

(Area

 

1.

WINDOWS: Heat gain from the sun.

 

 

Shades*

Shades*

Awnings* X Factor)

 

Northeast

*

These factors are for single glass

 

____sq. ft.

60

25

20 ____

Use

____

 

East

 

____sq. ft.

80

40

25 ____

only

____

 

 

only. For glass block, multiply the

 

 

Southeast

 

 

____sq. ft.

75

30

20 ____

the

____

 

 

above factors by 0.5; for double

 

 

South

 

 

____sq. ft.

75

35

20 ____

largest

____

 

 

glass or storm windows, multiply the

 

Southwest

 

____sq. ft.

110

 

30 ____

load.

____

 

 

above factors by 0.8.

 

45

 

West

 

 

 

____sq. ft.

150

65

45 ____

Use

____

 

Northwest

 

 

 

____sq. ft.

120

50

35 ____

only

____

 

North

 

 

 

____sq. ft.

0

0

0 ____

one.

____

 

 

 

 

 

 

 

 

 

 

2.

WINDOWS: Heat by conduction

 

 

 

 

 

 

 

 

 

(Total of all windows.)

 

 

 

 

 

 

 

 

 

Single glass

 

 

____sq. ft.

 

14

 

 

 

_____

 

Double glass or glass block

 

____sq. ft.

 

7

 

 

 

_____

 

 

 

 

 

 

 

3.

WALLS: (Based on linear feet of wall)

 

Light Construction

Heavy Construction

 

 

a. Outside walls

 

 

 

 

 

 

 

 

 

North Exposure

 

____ ft.

30

 

20

 

_____

 

Other than North exposure

 

____ ft.

60

 

30

 

_____

 

b. Inside Walls (between conditioned and

 

 

 

 

 

 

 

 

 

unconditioned spaces only.)

 

____sq. ft.

 

30

 

 

 

_____

 

 

 

 

 

 

 

 

 

 

4.

ROOF OR CEILING: (Use one only)

 

 

 

 

 

 

 

 

 

a. Roof, uninsulated

 

____sq. ft.

 

19

 

 

 

_____

 

b. Roof, 1 inch or more insulation

 

____sq. ft.

 

8

 

 

 

_____

 

c. Ceiling, occupied space above

 

____sq. ft.

 

3

 

 

 

_____

 

d. Ceiling, insulated, with attic space above

 

____sq. ft.

 

5

 

 

 

_____

 

e. Ceiling, uninsulated, with attic space above

 

____sq. ft.

 

12

 

 

 

_____

 

 

 

 

 

 

 

 

 

5.

Floor: (Disregard if fl oor is directly on ground or

____sq. ft.

 

3

 

 

 

_____

 

over a basement.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6.

NUMBER OF PEOPLE

 

____

 

600

 

 

 

_____

 

 

 

 

 

 

 

 

 

7.

LIGHTS AND ELECTRICAL EQUIPMENT IN USE

____watts

 

3

 

 

 

_____

 

 

 

 

 

 

 

 

 

 

8.

DOORS AND ARCHES CONTINUOUSLY

 

 

 

 

 

 

 

 

 

OPENED TO UNCONDITIONED SPACE: (TOTAL

____ft.

 

300

 

 

 

_____

 

LINEAR FEET OF WIDTH.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9.

SUBTOTAL

 

 

*****

 

*****

 

 

 

_____

 

 

 

 

 

 

 

 

10. TOTAL COOLING LOAD (BTU per hour to be used

 

 

 

 

 

 

 

 

for selection of room air conditioner(s).)

____ Total in Item 9 X ____

(Factor from Map) =

____

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

40

Page 41
Image 41
Friedrich XQ06M10, EQ08M11, XQ05M10, XQ10M10, XQ08M10 Cooling Load Estimate Form, Heat Gain from Quantity Factors, Day

XQ08M10, XQ10M10, XQ05M10, XQ06M10, EQ08M11 specifications

Friedrich offers a range of innovative air conditioning units designed to provide superior comfort and energy efficiency. Among its lineup, the XQ06M10, EQ08M11, XQ05M10, XQ08M10, and XQ10M10 models stand out due to their advanced technologies and user-friendly features.

The XQ series, with models like XQ06M10 and XQ05M10, is renowned for its sleek design and exceptional performance in cooling and heating environments. These models utilize a highly efficient compressor system that reduces energy consumption while maintaining optimal temperature control. The XQ06M10, for example, is designed for medium-sized rooms, featuring a cooling capacity that caters well to residential and small office settings.

On the other hand, the EQ08M11 model is known for its enhanced energy efficiency compared to traditional units, thanks to its inverter technology. This feature allows the compressor to adjust its speed according to the cooling demand, resulting in lower energy costs and a quieter operation. The EQ08M11 is also equipped with a multi-stage filtration system, improving indoor air quality by capturing dust, allergens, and pollutants.

The XQ08M10 and XQ10M10 cater to larger spaces, with their respective higher cooling capacities making them suitable for bigger living areas or small commercial settings. Both models boast an easy-to-use digital control panel, which requires minimal effort to adjust settings. Additionally, they include a programmable timer feature, allowing users to automate operation according to their daily schedules, further enhancing energy savings.

All these models showcase Friedrich’s commitment to durability and reliability, built with high-grade materials designed to withstand varying temperatures and humidity levels. The XQ series is compact, facilitating easy installation without compromising performance.

In summary, the Friedrich XQ06M10, EQ08M11, XQ05M10, XQ08M10, and XQ10M10 models combine cutting-edge technology with practicality, ensuring an efficient and enjoyable indoor climate. With features aimed at energy efficiency, ease of use, and effective air filtration, these units represent a smart investment for anyone looking to enhance their living or working environment.