Page 13
Image 13
CHECK FILTER

ALERTS (The control system has five (5) customer alerts)

CHECK FILTER

 

 

 

 

 

appears on screen. The word “

 

” appears next to the

 

button.

The

alert is issued when the fan

run time is greater than 500 hours.

This alert may be reset by the user (Refer to Special Functions, Filter Reset).

Maintenance Required – When maintenance is required, a service icon

Special Functions appears on screen. This icon will not be dismissed until maintenance has been performed. If the service icon Manual backgroundManual background

the icon Manual background is on standby the system has sensed an abnormal condition.

is established the service icon Manual background goes away.

Wait – The WAIT icon Manual background illuminates when the compressor lockout is active. Whenever the compressor shuts off, system pressures must be allowed to equalize. At this time, an internal timer begins a count-down from up to 240 seconds. If a demand for heat or cool occurs during this count-down

the WAIT icon Manual background displays letting you know that the compressor will not operate until the count-down has completed. This timer prevents damage to the unit if it tries to start too quickly after it stops running. Normally the

WAIT icon Manual background is off. Once the timer has cleared, the air conditioner will heat or cool based on the temperature setting. Electric heat is not affected by this timer.

Protection Alert (Freeze) – If the room freeze protection is active, the display indicates this by showing Room Freeze Protection "FRZ". Once

temperature is less than 40° F (4° C), and the air conditioner is equipped with electric heat, the room freeze protection will activate. The air conditioner will run high fan and electric heat until the room temperature reaches

46° F (8° C). Pressing the Manual background button delays the freeze protection function

Low Battery – When the battery is low a warning display Manual backgroundManual backgroundManual background will be inserted before other messages such as “COOL”. If the Low Battery Manual backgroundManual backgroundManual background alert is on, the battery in the control unit must be changed. Refer to the changing the battery procedure. Once the battery is changed, the alert message will go off. Refer to Troubleshooting Tips. Under normal conditions the battery life should be greater than 7 years.

Special Functions

Panel Lock Manual background – The front panel push buttons can be locked to prevent inadvertent operation. To lock the front panel, press and hold the SCHEDULE + Manual background buttons for three (3) seconds. A double beep indicates your mode change was successful and a Manual background icon appears on the display. To unlock

the display, press and hold the SCHEDULE + Manual background buttons for three (3) seconds. The Manual background icon will no longer be visible.

Filter Reset Manual backgroundManual backgroundManual backgroundManual backgroundManual background icon displays, the timer may be reset by pressing

and holding the Manual backgroundManual background button for three (3) seconds. A beep indicates the

Manual background system timer was reset and the Manual backgroundManual backgroundManual background icon and the word " RESE T " will no longer be visible.

User Menu Functions – The User Menu Functions allows you to change the following selections: Set TIME, 12/24 Hour Clock Format, BEEP ON / OFF, DIM ON / OFF, Emergency Heat (EMHT) ON / OFF, Auto BAND Adjust, F/ C Select, FRZ ON / OFF, Temp Offset (TO) and the Automatic Temperature Sensing Feature (ATSF).

To enter the User Menu, press and hold Manual background for 3 seconds, the TIME

selection appears. Use the Manual background (UP) or Manual background (DOWN) buttons to scroll

through the User Menu. Press the Manual background button to enter the displayed function. If left inactive for 15 minutes the User Menu display will no longer be visible and it returns to normal operation mode display. To manually

exit the User Menu, press the Manual background button.

The hour digits flash first. The user presses the

or

to change the hours. To change AM-PM, the hours must be

advanced 12 hours. Press the

key to change to the

minutes. To exit the selection process, user presses the

key which will go to the time screen.

 

The minutes digits flash. The user presses the

or

to change the minutes. Press the

key to change the days.

To exit the selection process, the user presses the

key

which will go to the time screen.

 

 

The dot underneath the days of the week begins to blink to indicate which day it is. If the user has not set the date before, the dot starts on Monday. If the user is making a correction to previously set information the dot appears under whichever

day the unit thinks it is. The user can press Manual background or Manual background to move the dot left or right (respectively) along the week. The user

presses Manual background to loop back to the hours setting. To exit the

selection process, the user presses the Manual background key which will go to the time screen.

Tuesday has been selected. The user presses Manual background to loop back to the hours setting. To exit the selection process and accept the changes, the user presses the BACK key which will go to the time screen.

Time Setting – When in the User Menu, on the Control Panel, use the

(UP) and

(DOWN) to select TIME. Push

, the hours segment

 

(UP) and

(DOWN) to set the hour, then push

 

 

 

(UP) and

(DOWN)

to set the minutes, then push Manual background.

NOTE: If the AM or PM indicator is incorrect, push Manual background until the hours

Manual background (UP) or (DOWN) to advance

the hour segment 12 hours, then push Manual background. The day of the week

displays. Use the Manual background (UP) or Manual background (DOWN) to select the current

day. Press the Manual background key to save and go back to the TIME screen.

Press Manual background (UP) to go to the next menu 1224.

NOTE: Pressing the Manual background button again will exit the user menu function mode. Or simply leave the control inactive for 15 minutes and the control will return back to normal operation.