Friedrich R-410A Performance Data, Specifications, Kühl + Heat Pump, Kühl + Electric Heat

Models: R-410A

1 87
Download 87 pages 18.35 Kb
Page 8
Image 8
PERFORMANCE DATA

PERFORMANCE DATA

COOLING

EVAP. AIR TEMP. DEG.

CONDENSER

Discharge

Suction

 

Sub-

OPERATING

ELECTRICAL RATINGS

R-410A

 

BREAKER

F

 

 

PRESSURES

REF.

 

FUSE

PERFORMANCE

 

Super Heat

 

 

 

Voltage

DATA*

Discharge Air

Temp.

TEMP DEG. F

Temp

Temp

 

Cooling

Suction

Discharge

Amps

Amps

Locked Rotor

Charge in

 

60 Hertz

Drop F.

 

 

 

 

 

Cool

Heat

Amps

OZ.

 

Amps

SS08M10-A

53

27

115

157

62

12

31

151

400

6.1

 

32.0

24.0

115

15

SS10M10-A

52

28

119

150

65

15

28

145

455

8.0

 

50.0

51.0

115

15

SS12M10-A

50

30

118

163

60

12

23

137

435

10.0

 

57.0

35.0

115

15

SS14M10-A

49

31

121

170

56

10

22

132

425

12.0

 

63.0

29.0

115

15

YS10M10-A

56

24

114

150

64

12

14

152

395

7.8

7.6

34.5

33.0

115

15

SS12M30-A

49

31

116

158

62

13

21

142

405

4.8

 

30.0

33.0

230/208v

15

ES12M33-A

51

29

115

158

62

13

18

140

400

4.8

16.0

30.0

33.0

230/208v

15

YS12M33-A

49

31

116

167

65

16

21

140

455

5.2

5.1

26.0

34.5

230/208v

15

SS15M30-A

53

27

121

171

62

14

28

138

430

6.4

 

32.0

32.5

230/208v

15

ES15M33-A

53

27

121

171

62

14

28

138

430

6.4

16.0

32.0

32.5

230/208v

15

SM18M30-A

54

26

122

160

62

9

31

145

450

7.4

 

42.0

55.0

230/208v

15

EM18M34-A

54

26

122

160

62

9

31

145

450

7.4

19.5

42.0

55.0

230/208v

30

YM18M34-A

50

30

118

168

60

15

24

130

410

8.5

8.5

44.0

49.5

230/208v

15

SM21M30-A

48

32

124

170

55

10

28

137

455

9.4

 

46.0

55.0

230/208v

15

SM24M30-A

46

34

129

179

55

12

34

123

495

11.0

 

47.0

40.0

230/208v

20

EM24M34-A

46

34

129

179

55

12

34

123

495

11.0

 

47.0

40.0

230/208v

30

YL24M34-A

56

24

121

176

62

18

25

135

480

11.1

12.2

47.0

74.0

230/208V

30

SL28M30-A

47

33

126

181

58

12

26

133

430

13.5

 

60.0

78.5

230/208v

20

SL36M30-A

51

29

129

188

56

12

31

122

470

19.0

 

96.0

77.0

230/208v

30

*Rating Conditions: 80 degrees F, room air temp. & 50% relative humidity, with 95 degree F, outside air temp & 40% relative humidity, all systems use R-410A.

SPECIFICATIONS

 

 

 

 

 

 ENERGY STAR® qualified

 

 

 

 

 

 

 

 

 

 

 

 

Energy

Estimated

 

Room Side

 

 

 

 

 

 

 

 

 

 

 

 

Efficiency Yearly Moisture

Air

 

Net

 

 

Cooling

Heating

Volts

Cooling

Cooling

Heating

Heating

 

Ratio

Operating

Removal

Circulation

 

Weight

 

Model

Capacity Btu

Capacity Btu

Rated

Amps

Watts

Amps

Watts

COP

EER

Cost

Pints/HR

CFM

Sleeve

Lbs

 

Kühl

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 



SS08M10

7900

115

6.1

677

11.7

$54

1.0

265

S

99

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 



SS10M10

9500

115

7.7

848

11.2

$68

2.0

260

S

106



SS12M10

12000

115

10.0

1071

11.2

$86

3.0

300

S

112

 

SS14M10

14000

115

12.0

1444

9.7

$115

3.5

325

S

116

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 



SS12M30

11700/11200

230/208

4.8/4.9

1026/982

11.4/11.4

$82

2.8

275

S

112

 

SS15M30

14500/14300

230/208

6.4/6.8

1405/1385

10.3/10.3

$112

3.5

360

S

116

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 



SM18M30

17500/17200

230/208

7.4/8.0

1635/1617

10.7/10.7

$131

4.6

350

M

140

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 



SM21M30

20800/20700

230/208

9.4/10.3

2080/2070

10.0/10.0

$166

6.0

425

M

132



SM24M30

23500/23300

230/208

11.2/11.9

2500/2479

9.4/9.4

$200

10.0

390

M

152

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 



SL28M30

27800/27000

230/208

13.5/14.4

2865/2812

9.7/9.6

$229

8.5

600

L

193

 

SL36M30

36000/35700

230/208

19.0/20.5

4235/4200

8.5/8.5

$338

12.0

725

L

212

 

Kühl + Heat Pump

 

 

 

 

 

 

 

 

 

 

 

 

 



 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YS10M10*

9500

7500

115

7.8

812

7.6

743

3.0

11.7

$65

1.9

285

S

109



YS12M33

12100/12100

9400/9000

230/208

5.2/5.4

1120/1120

5.6/5.8

1132/1139

2.4

10.8/10.8

$89

3.0

265

S

115



YM18M34

18200/17800

15500/15400

230/208

8.5/8.9

1838/1798

8.5/8.7

1833/1761

2.6

9.9/9.9

$147

5.4

370

M

141



YL24M35

24000/23600

23500/23200

230/208

11.1/12.0

2474/2433

12.2/14.3

2610/2575

2.6

9.7/9.7

7.0

600

L

197

 

Kühl + Electric Heat

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ES12M33

11700/11200

10700/8900

230/208

4.8/4.9

1026/982

16.0/14.7

3500/2900

3.3

11.4/11.4

$82

2.8

275

S

113

 

ES15M33

14500/14300

10700/8900

230/208

6.4/6.8

1405/1385

16.0/14.7

3500/2900

3.0

10.3/10.3

$112

3.5

360

S

117

 

EM18M34

17500/17200

13000/10600

230/208

7.4/8.0

1635/1617

19.5/17.0

4200/3500

3.1

10.7/10.7

$131

4.6

350

M

141

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EM24M34

23500/23300

13000/10600

230/208

11.2/11.9

2500/2479

19.5/17.0

4200/3500

3.1

9.4/9.4

$200

10.0

390

M

153

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EL36M35

36000/35700

17300/14300

230/208

19.0/20.5

4235/4200

24.0/22.4

5500/4650

2.5

8.5/8.5

$338

12.0

725

L

213

*Operates on 115 volt and is not equipped with supplemental heat. Will not provide heat at temperatures below 40°F. Friedrich room air conditioners are designed to operate in outdoor temperatures from 60° F to 115° F.

Due to continuing research in new energy-saving technology, specifications are subject to change without notice.

As an ENERGY STAR® partner, Friedrich Air Conditioning Co. has determined that the selected ENERGY STAR® () models meet the ENERGY STAR® guidelines for energy efficiency.

The consumer- through the AHAM Room Air Conditioner Certification Program- can be certain that the AHAM Certification Seal accurately states the unit’s cooling and heating capacity rating, the amperes and the energy efficiency ratio.

Estimated yearly operating cost based on a 2007 national average electricity cost of 10.65 cents per kWh.

† The estimated yearly operating cost of this model was not available at the time the range was published.

R-410A

All models use

environmentally friendly R-410A refrigerant.

7

Page 8
Image 8
Friedrich R-410A service manual Performance Data, Specifications, Kühl + Heat Pump, Kühl + Electric Heat