Friedrich R-410A service manual Replacement Instructions, Kühl User Interface Service Kit

Models: R-410A

1 87
Download 87 pages 18.35 Kb
Page 80
Image 80
Kühl User Interface Service Kit

Kühl User Interface Service Kit

Replacement Instructions

For Use with Kühl (cool only models) and Kühl + (cool and heat models)

ATTENTION! - Please read these instructions completely before attempting replacement. Always unplug the power supply from the power supply receptacle.

Contents:

User Interface (UI)

Ribbon Cable

2 – Mounting screws for UI

Instruction Sheet

Step 1. Disconnect ribbon cable by pulling straight out

Step 2. Remove 2 –mounting screws securing UI and disconnect ribbon cable Step 3. Remove UI and ribbon cable from handle assembly

Step 4. Install new UI using the 2-screws, route new ribbon cable and reattach ribbon cable to UI and Main control board

Step 5. Verify control operation

Ribbon cable connection

Mounting screws

79

Page 80
Image 80
Friedrich R-410A Replacement Instructions, Kühl User Interface Service Kit, Ribbon cable connection Mounting screws