Friedrich R410A manual Components Testing, Testing the Diagnostic Service Module

Models: R410A

1 61
Download 61 pages 11.89 Kb
Page 18
Image 18
COMPONENTS TESTING

COMPONENTS TESTING

Testing the Diagnostic Service Module

Testing the Electronic Control Board

Testing the Diagnostic Service ModuleWARNING

ELECTRIC SHOCK HAZARD

Turn off electric power before service or installation. Extreme care must be used, if it becomes necessary to work on equipment with power applied.

Failure to do so could result in serious injury or death.

If the Diagnostic Service Module does not turn on:

1.Make sure there is 208/230 VAC to the unit and that it is turned on.

2.Disconnect the diagnostic service module’s wire harness on the control board.

3.Using a voltmeter, check the fi rst two pins to the left of the female connector (see picture below). There should be up to 5VDC.

4.If there is no voltage, replace the electronic control board.

5.If there is voltage, check the wire harness and connections at the electronic control board and the diagnostic service module.

6.If the connections and the wire harness are good, replace the diagnostic service module.

Diagnostic Service Module

Service Module Connector

Test here up to 5VDC.

If no voltage, replace board.

If there is 5VDC, check connections

and cable. If OK, replace service module.

17

Page 18
Image 18
Friedrich R410A manual Components Testing, Testing the Diagnostic Service Module, Testing the Electronic Control Board