For VPAK Cool with Electric Heat 24K

 

For VPAK Cool with Electric Heat 24K

 

For VPAK Heat Pumps 24K

 

 

 

 

 

 

 

 

 

 

 

 

ELECTRICAL DATA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VEA24K

 

 

 

 

 

VHA24K

 

 

Heater Watts

2500/2050

3400/2780

5000/4090

7500/6135

10000/8180

2500/2050

 

3400/2780

5000/4090

7500/6135

10000/8180

Voltage

 

 

230/208

 

 

 

 

 

230/208

 

 

Heating BTU/h

8500/7000

11600/9500

17000/13900

25598/20939

34130/27918

8500/7000

 

11600/9500

17000/13900

25598/20939

34130/27918

Heating Current (Amps)

10.9/9.9

14.8/13.4

21.7/19.7

32.6/29.5

43.5/39.3

10.9/9.9

 

14.8/13.4

21.7/19.7

32.6/29.5

43.5/39.3

Minimum Circuit Ampacity

17.2/15.9

22.1/20.3

30.7/28.1

44.3/40.3

57.9/52.7

17.2/15.9

 

22.1/20.3

30.7/28.1

44.3/40.3

57.9/52.7

Branch Circuit Fuse (Amps)

25

25

30

45

60

25

 

25

30

45

60

LRA - Compressor (Amps)

34.8

34.8

34.8

34.8

34.8

34.8

 

34.8

34.8

34.8

34.8

Cooling Current (Amps)

10.0/10.4

10.0/10.4

10.0/10.4

10.0/10.4

10.0/10.4

10.6/10.9

 

10.6/10.9

10.6/10.9

10.6/10.9

10.6/10.9

Basic heater Size

2.5 Kw

3.4 Kw

5.0 Kw

7.5 Kw

10.0 Kw

2.5 Kw

 

3.4 Kw

5.0 Kw

7.5 Kw

10.0 Kw

Power Connection

 

 

HARD WIRED

 

 

 

 

 

HARD WIRED

 

 

Recommended Branch

 

 

 

 

 

 

 

 

 

 

 

**Circuit Wire Sizes* AWG -

10

10

10

6

4

10

 

10

10

6

4

American Wire Gauge

 

 

 

 

 

 

 

 

 

 

 

Chassis Specifi cations

MODEL 2011

VEA09K

VEA12K

VEA18K

VEA24K

COOLING DATA

 

 

 

 

 

 

 

 

 

COOLING BTUH

9400/9000

11500/11200

17000/16500

23000/22700

POWER (W)

959

1173

1888

2421

EER

9.8/9.8

9.8/9.8

9.0/9.0

9.5/9.5

SENSIBLE HEAT RATIO

0.74

0.72

0.70

0.70

HEAT PUMP DATA

 

 

 

 

 

 

 

 

 

HEATING BTUH

 

N/A

 

COP @ 47F

 

N/A

 

HEATING POWER (W)

 

N/A

 

HEATING CURRENT (A)

 

N/A

 

ELECTRICAL DATA

 

 

 

 

 

 

 

 

 

VOLTAGE (1 PHASE, 60 HZ)

230/208

230/208

230/208

230/208

VOLT RANGE

253-198

253-198

253-198

253-198

COOLING CURRENT (A)

4.2/4.4

5.2/5.4

8.1/8.5

10.0/10.4

AMPS L.R.

19.8

30

42

34.8

AMPS F.L.

3.5

4.5

7.8

9.5

INDOOR MOTOR (HP)

1/4

1/4

1/4

1/4

INDOOR MOTOR (A)

1.2

1.2

1.2

1.94

OUTDOOR MOTOR (HP)

 

N/A

 

1/4

OUTDOOR MOTOR (A)

 

N/A

 

0.85

AIRFLOW DATA

 

 

 

 

INDOOR CFM*

300

350

450

610

VENT CFM

60

60

60

60

MAX. ESP

.3"

.3"

.3"

.4"

PHYSICAL

 

 

 

 

DIMENSIONS (W X D X H)

23X23X32

23X23X32

23X23X32

23X23X47

NET WEIGHT (LBS)

114

124

144

167

SHIPPING WEIGHT (LBS)

125

135

155

220

R410A CHARGE (OZ)

33.5

35.5

48

65

 

 

 

 

 

VHA09K

VHA12K

VHA18K

VHA24K

 

 

 

 

9200/9000

11500/11200

17000/16800

23000/22800

939

1186

1868

2527

9.8/9.8

9.7/9.7

9.1/9.1

9.1/9.1

 

 

 

 

0.74

0.72

0.70

0.70

 

 

 

 

8500

10800

16000

20000

3.0

3.0

3.0

3.0

 

 

 

 

830

1055

1563

1953

3.6

4.9

7.5

9.4

 

 

 

 

230/208

230/208

230/208

230/208

 

 

 

 

253-198

253-198

253-198

253-198

4.1/4.3

5.3/5.5

8.2/8.5

10.6/10.8

18.5

26

42

34.8

 

 

 

 

3.5

5

7.8

9.5

1/4

1/4

1/4

1/4

 

 

 

 

1.2

1.2

1.2

1.94

 

N/A

 

1/4

 

N/A

 

0.85

 

 

 

 

300

420

450

610

60

60

60

60

 

 

 

 

.3"

.3"

.3"

.4"

 

 

 

 

23X23X32

23X23X32

23X23X32

23X23X47

 

 

 

 

114

125

144

167

125

135

155

220

39

42

52

74

 

 

 

 

* NORMAL VALUE WET COIL @ .1"ESP.