| For VPAK Cool with Electric Heat 24K |
| For VPAK Heat Pumps 24K | ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
ELECTRICAL DATA |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| VEA24K |
|
|
|
|
| VHA24K |
|
|
Heater Watts | 2500/2050 | 3400/2780 | 5000/4090 | 7500/6135 | 10000/8180 | 2500/2050 |
| 3400/2780 | 5000/4090 | 7500/6135 | 10000/8180 |
Voltage |
|
| 230/208 |
|
|
|
|
| 230/208 |
|
|
Heating BTU/h | 8500/7000 | 11600/9500 | 17000/13900 | 25598/20939 | 34130/27918 | 8500/7000 |
| 11600/9500 | 17000/13900 | 25598/20939 | 34130/27918 |
Heating Current (Amps) | 10.9/9.9 | 14.8/13.4 | 21.7/19.7 | 32.6/29.5 | 43.5/39.3 | 10.9/9.9 |
| 14.8/13.4 | 21.7/19.7 | 32.6/29.5 | 43.5/39.3 |
Minimum Circuit Ampacity | 17.2/15.9 | 22.1/20.3 | 30.7/28.1 | 44.3/40.3 | 57.9/52.7 | 17.2/15.9 |
| 22.1/20.3 | 30.7/28.1 | 44.3/40.3 | 57.9/52.7 |
Branch Circuit Fuse (Amps) | 25 | 25 | 30 | 45 | 60 | 25 |
| 25 | 30 | 45 | 60 |
LRA - Compressor (Amps) | 34.8 | 34.8 | 34.8 | 34.8 | 34.8 | 34.8 |
| 34.8 | 34.8 | 34.8 | 34.8 |
Cooling Current (Amps) | 10.0/10.4 | 10.0/10.4 | 10.0/10.4 | 10.0/10.4 | 10.0/10.4 | 10.6/10.9 |
| 10.6/10.9 | 10.6/10.9 | 10.6/10.9 | 10.6/10.9 |
Basic heater Size | 2.5 Kw | 3.4 Kw | 5.0 Kw | 7.5 Kw | 10.0 Kw | 2.5 Kw |
| 3.4 Kw | 5.0 Kw | 7.5 Kw | 10.0 Kw |
Power Connection |
|
| HARD WIRED |
|
|
|
|
| HARD WIRED |
|
|
Recommended Branch |
|
|
|
|
|
|
|
|
|
|
|
**Circuit Wire Sizes* AWG - | 10 | 10 | 10 | 6 | 4 | 10 |
| 10 | 10 | 6 | 4 |
American Wire Gauge |
|
|
|
|
|
|
|
|
|
|
|
Chassis Specifi cations
MODEL 2011 | VEA09K | VEA12K | VEA18K | VEA24K |
COOLING DATA |
|
|
|
|
|
|
|
|
|
COOLING BTUH | 9400/9000 | 11500/11200 | 17000/16500 | 23000/22700 |
POWER (W) | 959 | 1173 | 1888 | 2421 |
EER | 9.8/9.8 | 9.8/9.8 | 9.0/9.0 | 9.5/9.5 |
SENSIBLE HEAT RATIO | 0.74 | 0.72 | 0.70 | 0.70 |
HEAT PUMP DATA |
|
|
|
|
|
|
|
|
|
HEATING BTUH |
| N/A |
| |
COP @ 47F |
| N/A |
| |
HEATING POWER (W) |
| N/A |
| |
HEATING CURRENT (A) |
| N/A |
| |
ELECTRICAL DATA |
|
|
|
|
|
|
|
|
|
VOLTAGE (1 PHASE, 60 HZ) | 230/208 | 230/208 | 230/208 | 230/208 |
VOLT RANGE | ||||
COOLING CURRENT (A) | 4.2/4.4 | 5.2/5.4 | 8.1/8.5 | 10.0/10.4 |
AMPS L.R. | 19.8 | 30 | 42 | 34.8 |
AMPS F.L. | 3.5 | 4.5 | 7.8 | 9.5 |
INDOOR MOTOR (HP) | 1/4 | 1/4 | 1/4 | 1/4 |
INDOOR MOTOR (A) | 1.2 | 1.2 | 1.2 | 1.94 |
OUTDOOR MOTOR (HP) |
| N/A |
| 1/4 |
OUTDOOR MOTOR (A) |
| N/A |
| 0.85 |
AIRFLOW DATA |
|
|
|
|
INDOOR CFM* | 300 | 350 | 450 | 610 |
VENT CFM | 60 | 60 | 60 | 60 |
MAX. ESP | .3" | .3" | .3" | .4" |
PHYSICAL |
|
|
|
|
DIMENSIONS (W X D X H) | 23X23X32 | 23X23X32 | 23X23X32 | 23X23X47 |
NET WEIGHT (LBS) | 114 | 124 | 144 | 167 |
SHIPPING WEIGHT (LBS) | 125 | 135 | 155 | 220 |
R410A CHARGE (OZ) | 33.5 | 35.5 | 48 | 65 |
|
|
|
|
|
VHA09K | VHA12K | VHA18K | VHA24K |
|
|
|
|
9200/9000 | 11500/11200 | 17000/16800 | 23000/22800 |
939 | 1186 | 1868 | 2527 |
9.8/9.8 | 9.7/9.7 | 9.1/9.1 | 9.1/9.1 |
|
|
|
|
0.74 | 0.72 | 0.70 | 0.70 |
|
|
|
|
8500 | 10800 | 16000 | 20000 |
3.0 | 3.0 | 3.0 | 3.0 |
|
|
|
|
830 | 1055 | 1563 | 1953 |
3.6 | 4.9 | 7.5 | 9.4 |
|
|
|
|
230/208 | 230/208 | 230/208 | 230/208 |
|
|
|
|
4.1/4.3 | 5.3/5.5 | 8.2/8.5 | 10.6/10.8 |
18.5 | 26 | 42 | 34.8 |
|
|
|
|
3.5 | 5 | 7.8 | 9.5 |
1/4 | 1/4 | 1/4 | 1/4 |
|
|
|
|
1.2 | 1.2 | 1.2 | 1.94 |
| N/A |
| 1/4 |
| N/A |
| 0.85 |
|
|
|
|
300 | 420 | 450 | 610 |
60 | 60 | 60 | 60 |
|
|
|
|
.3" | .3" | .3" | .4" |
|
|
|
|
23X23X32 | 23X23X32 | 23X23X32 | 23X23X47 |
|
|
|
|
114 | 125 | 144 | 167 |
125 | 135 | 155 | 220 |
39 | 42 | 52 | 74 |
|
|
|
|
* NORMAL VALUE WET COIL @ .1"ESP.