Unplug unit when servicing.

920-197-01

STEP 6 Inspect the unit before inserting it into the sleeve. The fan and blower wheel should be manually rotated to insure that they turn freely. Be sure the electrical cord will be out of the way when inserting the unit into the sleeve.

NOTE: For your safety, DO NOT plug the electrical cord into an electrical outlet until installation is complete.

STEP 7 If the unit checks out OK, it is ready to be placed into position on bottom rails of the cabinet and pushed into place.

NOTE: Do all lifting of the unit by the bottom pan only and with assistance or help as necessary (see Figure A).

STEP 8 Install the white chassis seal gasket (item #6, page 6) and the gray window seal gasket (item #5). Carefully insert the white gasket (item #6) between the chassis and the cabinet starting at either bottom corner and go up the side, across the top and down the opposite side. Insert the gray gasket (item #5) between the window sashes as shown in Figure D. If chassis seal gasket is not installed, the operation of the unit will be negatively affected. Also, the operation noise and outside noise will be amplified.

STEP 9 Hold the decorative front as shown in Figure E. Insert the two tabs of the Decorative Front Panel into the slots in the top of the cabinet and lower the bottom of the decorative front to the bottom of the cabinet. Route the electrical cord to the right or left side of the bottom of the cabinet as required by the location of the electrical wall outlet. Use the notches provided at the bottom of the Decorative Front Panel for routing the electrical cord out of the unit. Attach the decorative front to the cabinet with two (2) No. 8 x ½" Phillips head screws (item #2, page 6).

Figure DWARNING

Electrical Shock Hazard

Unplug unit when servicing.

Failure to follow these instructions can result in death, fire, or electrical shock.

Figure D

GRAY FOAM GASKET (see illustration, item #5 on page 6)

CHASSIS SEAL GASKET

TO PREVENT AIR LEAKS AROUND

THE AIR CONDITIONER, INSERT

THE WHITE FOAM GASKET (item

# 6, page 6) BETWEEN THE AIR CONDITIONER AND THE CABINET.

Figure E

TAB SLOTS

TAB

LOCATIONS

NOTCHES PROVIDED

FOR ELECTRICAL

CORD EXIT

SCREW, #8 x ½" PHILLIPS HEAD (See ilustration, item # 2, page 6)

2 REQUIRED (1 EACH SIDE)

STEP 10 CIRCUIT PROTECTION - If the air conditioner is circuit protected by a fuse, use a "TIME DELAY" fuse or HACR type Circuit Breaker due to momentary high current demand when your air conditioner is started. Before operating your unit, verify the ampere rating of the time-delay fuse or circuit breaker which protects your unit. The ampere rating of the time-delay fuse or circuit breaker shall be 15 amps. Refer to Operation section for more detailed operating instructions.

Figure ECAUTION

Excessive Weight Hazard

Use two or more people when installing your air conditioner.

Failure to do so can result in back or other injury.

Manual backgroundWARNING

Moving Object Hazard

Replace all panels before operating your air conditioner.

Failure to do so can result in injury.