PROBLEM

PROBABLE CAUSES

CORRECTIVE ACTION

 

A. Failed/shorted temperature probe.

A. If resistance is out of

 

Test: Check for shorted probe

specification, replace the

 

temperature probe.

 

circuit. Probe resistance should be

 

 

Water boils in simmer

approximately 552 Ohms @ 60°F

 

mode.

(16°C), 655 Ohms @ 100°F

 

 

(38°C), and 1000 Ohms @ 212°F

 

 

(100°C). See probe resistance

 

 

chart on page 1-17 for other

 

 

temperatures.

 

 

A. Controller out of calibration

A. Recalibrate simmer setpoint.

Water temperature too

B. Temperature probe open.

B. If connections are secure, re-

low in simmer mode.

Test: Check for loose

place temperature probe.

 

 

 

 

connections.

 