1.3.3 Replacing a
1.Drain the cookpot and disconnect the cooker from the electrical power supply.
2.Remove the screws in the upper edge of the control panel and swing the panel down. Disconnect the
3.Remove the topcap from the unit by removing the four screws (two on the front and two on each end) that secure it to the cabinet.
4.Remove the control panel frame by removing the screws in the top and bottom corners and the screw in the center bracket.
5.If replacing a
a.Disconnect the sensor lead by pulling it from its terminal then remove the Keps nut, terminal, and washer from the sensor.
b.Inside the cookpot, remove the screw from the sensor flange.
c.Carefully pull the failed sensor from the probe block and replace with the new sensor.
d.Reassemble the washer, terminal, and nut onto the sensor, and reattach the lead.
e.Reverse Steps 1-4 to complete the procedure.
If replacing the temperature probe, mark the wiring harness leads and disconnect the probe leads at the push on connectors.
Remove the screws from the probe bracket and push the probe out the back of the probe block.
Temperature Probe
If replacing a
Remove the screw from the sensor flange and pull the sensor out the front of the probe block.
6.If replacing the temperature probe (see illustration above):
a.Mark the wiring harness leads and disconnect them from the probe leads at the
b.Remove the two screws in the probe bracket.
c.Carefully pull the probe from the probe block and replace with the new probe.
d.Reattach the leads and reverse Steps
1.3.4 Replacing the Pressure Regulator or Solenoid Valve
1.Drain the cookpot and disconnect the cooker from the electrical power supply. Turn off or disconnect the water supply to the cooker.