INTERNATIONAL KESSEL SERVICE

Problem

 

Probable Causes

Corrective Action

 

 

 

If available, substitute a controller

 

 

 

known to be working for the

Fryer heats until

 

suspect controller. If the substitute

 

controller functions correctly,

high-limit trips

Contactor or controller has failed.

order a new controller from FASC.

without heat

If substitution of the controller

 

indicator ON.

 

does not resolve the problem, the

 

 

 

most likely cause is a contactor

 

 

 

failed in the closed position. Call

 

 

 

FASC.

 

 

 

The fact that the heat indicator is

 

 

 

ON indicates that the controller is

 

 

 

functioning properly and is calling

 

 

 

for heat. The high-limit thermostat

 

 

 

functions as a normally closed

Fryer stops heating

 

switch. If the thermostat fails, the

The high-limit thermostat or

"switch" opens and power to the

with heat indicator

contactor has failed.

elements is shut off. If the

 

ON.

 

 

contactor fails to close, no power is

 

 

 

 

 

 

supplied to the elements.

 

 

 

Determining which component has

 

 

 

failed is beyond the scope of

 

 

 

operator troubleshooting. Call

 

 

 

FASC.

6.2.2 Error Messages and Display Problems

 

 

 

 

 

Problem

 

Probable Causes

Corrective Action

 

 

 

Verify that the drain valve is fully

 

 

 

closed. The fryer will not function

Basket lift timer

 

if the drain valve is not fully

Open drain valve or problem with

closed. If the drain valve is fully

display shows

latching circuits

closed, the problem is within the

 

.

 

 

latching circuitry and is beyond the

 

 

 

 

 

 

scope of operator trouble shooting.

 

 

 

Call FASC.

 

 

 

This in an indication of a

Basket lift timer

Frypot temperature is more than

malfunction in the temperature

control circuitry, including a

410ºF (210ºC) or, in CE countries,

display shows

.

failure of the high-limit thermostat.

395ºF (202ºC).

 

 

Shut the fryer down immediately

 

 

 

 

 

 

and call FASC.

WWW.INTERNATIONALKESSEL6-4.COM