INTERNATIONAL KESSEL SERVICE
Problem |
| Probable Causes | Corrective Action | |
|
|
| If available, substitute a controller | |
|
|
| known to be working for the | |
Fryer heats until |
| suspect controller. If the substitute | ||
| controller functions correctly, | |||
Contactor or controller has failed. | order a new controller from FASC. | |||
without heat | If substitution of the controller | |||
| ||||
indicator ON. |
| does not resolve the problem, the | ||
|
|
| most likely cause is a contactor | |
|
|
| failed in the closed position. Call | |
|
|
| FASC. | |
|
|
| The fact that the heat indicator is | |
|
|
| ON indicates that the controller is | |
|
|
| functioning properly and is calling | |
|
|
| for heat. The | |
|
|
| functions as a normally closed | |
Fryer stops heating |
| switch. If the thermostat fails, the | ||
The | "switch" opens and power to the | |||
with heat indicator | ||||
contactor has failed. | elements is shut off. If the | |||
| ON. | |||
|
| contactor fails to close, no power is | ||
|
|
| ||
|
|
| supplied to the elements. | |
|
|
| Determining which component has | |
|
|
| failed is beyond the scope of | |
|
|
| operator troubleshooting. Call | |
|
|
| FASC. | |
6.2.2 Error Messages and Display Problems |
| |||
|
|
|
| |
Problem |
| Probable Causes | Corrective Action | |
|
|
| Verify that the drain valve is fully | |
|
|
| closed. The fryer will not function | |
Basket lift timer |
| if the drain valve is not fully | ||
Open drain valve or problem with | closed. If the drain valve is fully | |||
display shows | ||||
latching circuits | closed, the problem is within the | |||
| . | |||
|
| latching circuitry and is beyond the | ||
|
|
| ||
|
|
| scope of operator trouble shooting. | |
|
|
| Call FASC. | |
|
|
| This in an indication of a | |
Basket lift timer | Frypot temperature is more than | malfunction in the temperature | ||
control circuitry, including a | ||||
410ºF (210ºC) or, in CE countries, | ||||
display shows | . | failure of the | ||
395ºF (202ºC). | ||||
|
| Shut the fryer down immediately | ||
|
|
| ||
|
|
| and call FASC. |