INTERNATIONAL KESSEL SERVICE
Problem | Probable Causes | Corrective Action | |
|
| This display is normal when the | |
|
| fryer is first turned on and may | |
|
| appear for a short while if a large | |
|
| batch of frozen product is added to | |
|
| the frypot. If the display never | |
|
| goes out, the fryer is not heating. | |
|
| Look for a decimal in the LED | |
|
| display between digits 1 and 2. If | |
|
| the decimal is present, the | |
CM III |
| computer is calling for heat and is | |
| functioning properly. See Fryer | ||
or | Frypot temperature is more than 21ºF | ||
Digital Controller | (12ºC) below setpoint. | Does Not Heat in Control and | |
Heating Problems (Section 6.2.1). | |||
display shows . |
| ||
| If the decimal is not present, the | ||
|
| ||
|
| computer is not calling for heat and | |
|
| may be malfunctioning. If | |
|
| available, substitute a controller | |
|
| known to be working for the | |
|
| suspect computer. If the fryer | |
|
| functions correctly with the | |
|
| substitute computer, order a | |
|
| replacement computer from your | |
|
| FASC. | |
CM III |
| This indicates a problem within the | |
or | Problem with the temperature | temperature measuring circuitry | |
Digital Controller | measuring circuitry including the | that is beyond the scope of | |
display shows | probe. | operator troubleshooting. Shut the | |
. |
| fryer down and call FASC. | |
|
| The CM III computer may be | |
|
| programmed for constant | |
CM III frypot |
| temperature display or countdown | |
Computer is programmed for | timer display. Refer to the separate | ||
temperature is | |||
constant temperature display. | Frymaster Fryer Controllers | ||
displayed constantly. | |||
| User's Manual for instructions on | ||
|
| ||
|
| toggling between these display | |
|
| options. | |
|
| This in an indication of a | |
|
| malfunction in the temperature | |
|
| measuring or control circuitry, | |
Solid state controller | Oil temperature above acceptable | including a failure of the | |
range or a problem with the | thermostat. Determining the | ||
trouble light ON. | |||
temperature measuring circuitry. | specific problem is beyond the | ||
| |||
|
| scope of operator troubleshooting. | |
|
| Shut the fryer down immediately | |
|
| and call FASC. |