INTERNATIONAL KESSEL SERVICE

Problem

Probable Causes

Corrective Action

 

 

A. If using filter paper or pad

 

 

configuration, verify that filter

 

A. Improperly installed filter pan

screen is in bottom of pan with

 

paper or pad on top of screen.

 

components.

Verify that o-rings are present

 

 

 

 

and in good condition on filter

Filter pump runs,

 

pan connection fitting.

 

 

but oil return is very

 

B. In order to properly filter, the

slow and bubbling

 

oil or shortening should be at

oil comes out of the

 

or near 350ºF (177ºC). At

Power Shower.

 

temperatures lower than this,

 

 

the oil/shortening becomes too

 

B. Attempting to filter with oil or

thick to pass through the filter

 

medium easily, resulting in

 

shortening that is not hot enough.

 

much slower oil return and

 

 

 

 

eventual overheating of the

 

 

filter pump motor. Make sure

 

 

oil/shortening is at or near

 

 

frying temperature before

 

 

draining oil into filter pan.

 

A. Missing or worn Power Shower

A. Verify that the gasket is present

 

gasket.

and in good condition.

 

 

B. If the Power Shower is not

 

 

cleaned on a routine basis,

 

 

sediment will eventually block

 

 

the small holes around the edges

Power Shower not

 

of the frame. Also, when using

 

solid shortening, if the Power

spraying properly.

B. Clogged openings in Power

Shower is not allowed to drain

 

Shower frame.

completely, the shortening will

 

 

solidify in the holes and may fill

 

 

the frame. Completely drain the

 

 

Power Shower after each

 

 

filtering and clean regularly in

 

 

accordance with the instructions

 

 

in Chapter 5 of this manual.

6.3Replacing the Controller or Controller Wiring Harness

1.Disconnect the fryer from the electrical supply, remove the two screws in the upper corners of the control panel and swing the panel open from the top, allowing it to rest on its hinge tabs.

2.Disconnect the wiring harness from the back of the controller. If replacing the harness, disconnect it from the interface board. If replacing the controller, disconnect the ground wire and remove the controller by lifting it from the hinge slots in the control panel frame.

3.Reverse the procedure to install a new controller or wiring harness.

WWW.INTERNATIONALKESSEL6-8.COM