INTERNATIONAL KESSEL SERVICE
Problem | Probable Causes | Corrective Action |
|
| A. If using filter paper or pad |
|
| configuration, verify that filter |
| A. Improperly installed filter pan | screen is in bottom of pan with |
| paper or pad on top of screen. | |
| components. | Verify that |
|
| |
|
| and in good condition on filter |
Filter pump runs, |
| pan connection fitting. |
|
| |
but oil return is very |
| B. In order to properly filter, the |
slow and bubbling |
| oil or shortening should be at |
oil comes out of the |
| or near 350ºF (177ºC). At |
Power Shower. |
| temperatures lower than this, |
|
| the oil/shortening becomes too |
| B. Attempting to filter with oil or | thick to pass through the filter |
| medium easily, resulting in | |
| shortening that is not hot enough. | |
| much slower oil return and | |
|
| |
|
| eventual overheating of the |
|
| filter pump motor. Make sure |
|
| oil/shortening is at or near |
|
| frying temperature before |
|
| draining oil into filter pan. |
| A. Missing or worn Power Shower | A. Verify that the gasket is present |
| gasket. | and in good condition. |
|
| B. If the Power Shower is not |
|
| cleaned on a routine basis, |
|
| sediment will eventually block |
|
| the small holes around the edges |
Power Shower not |
| of the frame. Also, when using |
| solid shortening, if the Power | |
spraying properly. | B. Clogged openings in Power | Shower is not allowed to drain |
| Shower frame. | completely, the shortening will |
|
| solidify in the holes and may fill |
|
| the frame. Completely drain the |
|
| Power Shower after each |
|
| filtering and clean regularly in |
|
| accordance with the instructions |
|
| in Chapter 5 of this manual. |
6.3Replacing the Controller or Controller Wiring Harness
1.Disconnect the fryer from the electrical supply, remove the two screws in the upper corners of the control panel and swing the panel open from the top, allowing it to rest on its hinge tabs.
2.Disconnect the wiring harness from the back of the controller. If replacing the harness, disconnect it from the interface board. If replacing the controller, disconnect the ground wire and remove the controller by lifting it from the hinge slots in the control panel frame.
3.Reverse the procedure to install a new controller or wiring harness.