DANGER

Do not attach an apron drainboard to a single fryer. The fryer may become unstable, tip over, and cause injury. The appliance area must be kept free and clear of combustible material at all times.

All installation and service on Frymaster equipment must be performed by qualified, certified, licensed, and/or authorized installation or service personnel. Service may be obtained by contacting your local Factory Authorized Service Center.

2.2Power Requirements

MODEL

VOLTAGE

PHASE

WIRE

 

MIN.

AWG

 

AMPS PER LEG

 

 

 

 

SERVICE

 

SIZE

(mm2)

L1

 

L2

L3

 

H14

208

3

3

 

6

(16)

39

 

39

39

 

H14

240

3

3

 

6

(16)

34

 

34

34

 

H14

480

3

3

 

8

(10)

17

 

17

17

 

H14

220/380

3

4

 

6

(16)

21

 

21

21

 

H14

240/415

3

4

 

6

(16)

20

 

20

21

 

H14

230/400

3

4

 

6

(16)

21

 

21

21

 

ALL

208

3

3

 

6

(16)

39

 

39

39

 

EPH14

240

3

3

 

6

(16)

34

 

34

34

 

SERIES

220/380

3

4

 

6

(16)

21

 

21

21

 

(SOLID STATE)

240/415

3

4

 

6

(16)

20

 

20

20

 

H17

208

3

3

 

6

(16)

48

 

48

48

 

H17

240

3

3

 

6

(16)

41

 

41

41

 

H17

480

3

3

 

6

(16)

21

 

21

21

 

H17

220/380

3

4

 

6

(16)

26

 

26

26

 

H17

240/415

3

4

 

6

(16)

24

 

24

24

 

`

230/400

3

4

 

6

(16)

25

25

25

 

ALL

208

3

3

 

6

(16)

48

48

48

 

EPH17

240

3

3

 

6

(16)

41

41

41

 

SERIES

220/380

3

4

 

6

(16)

26

 

26

26

 

(SOLID STATE)

240/415

3

4

 

6

(16)

24

 

24

24

 

2-2