INTERNATIONAL KESSEL SERVICE

Problem

Probable Causes

Corrective Action

Basket lift timer

 

This indicates a problem within the

Problem with the temperature

temperature measuring circuitry

display shows

measuring circuitry including the

that is beyond the scope of

.

probe.

operator troubleshooting. Shut the

 

 

fryer down and call FASC.

 

 

CM III computers may be

CM III display is in

 

programmed to display in either

 

Fahrenheit or Celsius. Refer to the

wrong temperature

 

Incorrect display option programmed.

separate Frymaster Fryer

scale (Fahrenheit or

 

Controllers User's Manual for

Celsius).

 

 

instructions on changing the

 

 

 

 

display.

 

 

Verify that the drain valve is fully

CM III

 

closed. The fryer will not function

 

if the drain valve is not fully

or

 

Open drain valve or problem with

closed. If the drain valve is fully

Digital Controller

latching circuitry.

closed, the problem is within the

display shows

 

latching circuitry and is beyond the

.

 

 

scope of operator trouble shooting.

 

 

 

 

Call FASC.

 

 

This display is normal if the fryer

 

 

setpoint has been changed to a

 

 

lower temperature. The display

 

 

should revert to the normal four

 

Fryer is more than 21ºF (12ºC) above

dashes when the frypot

display shows .

setpoint.

temperature cools to the setpoint.

If the setpoint has not been

 

 

 

 

changed, this indicates a problem

 

 

with the temperature control

 

 

circuitry. Turn the fryer off and

 

 

call FASC.

CM III

 

This in an indication of a

Frypot temperature is more than

malfunction in the temperature

or

control circuitry, including a

410ºF (210ºC) or, in CE countries,

Digital Controller

failure of the high-limit thermostat.

395ºF (202ºC).

display shows .

Shut the fryer down immediately

 

 

 

and call FASC.