INTERNATIONAL KESSEL SERVICE
Problem | Probable Causes | Corrective Action | |
Basket lift timer |
| This indicates a problem within the | |
Problem with the temperature | temperature measuring circuitry | ||
display shows | measuring circuitry including the | that is beyond the scope of | |
. | probe. | operator troubleshooting. Shut the | |
|
| fryer down and call FASC. | |
|
| CM III computers may be | |
CM III display is in |
| programmed to display in either | |
| Fahrenheit or Celsius. Refer to the | ||
wrong temperature |
| ||
Incorrect display option programmed. | separate Frymaster Fryer | ||
scale (Fahrenheit or | |||
| Controllers User's Manual for | ||
Celsius). |
| ||
| instructions on changing the | ||
|
| ||
|
| display. | |
|
| Verify that the drain valve is fully | |
CM III |
| closed. The fryer will not function | |
| if the drain valve is not fully | ||
or |
| ||
Open drain valve or problem with | closed. If the drain valve is fully | ||
Digital Controller | |||
latching circuitry. | closed, the problem is within the | ||
display shows | |||
| latching circuitry and is beyond the | ||
. |
| ||
| scope of operator trouble shooting. | ||
|
| ||
|
| Call FASC. | |
|
| This display is normal if the fryer | |
|
| setpoint has been changed to a | |
|
| lower temperature. The display | |
|
| should revert to the normal four | |
| Fryer is more than 21ºF (12ºC) above | dashes when the frypot | |
display shows . | setpoint. | temperature cools to the setpoint. | |
If the setpoint has not been | |||
|
| ||
|
| changed, this indicates a problem | |
|
| with the temperature control | |
|
| circuitry. Turn the fryer off and | |
|
| call FASC. | |
CM III |
| This in an indication of a | |
Frypot temperature is more than | malfunction in the temperature | ||
or | control circuitry, including a | ||
410ºF (210ºC) or, in CE countries, | |||
Digital Controller | failure of the | ||
395ºF (202ºC). | |||
display shows . | Shut the fryer down immediately | ||
| |||
|
| and call FASC. |