5.2.1 Control and Heating Problems (cont.)
Problem | Probable Causes | Corrective Action | |
Fryer heats until high- |
|
| |
limit trips without | Contactor or controller has failed. | Call FASC. | |
heat indicator ON. |
|
| |
|
| The fact that the heat indicator is ON | |
|
| indicates that the controller is | |
|
| functioning properly and is calling for | |
|
| heat. The | |
Fryer stops heating |
| functions as a normally closed switch. | |
The | If the thermostat fails, the "switch" | ||
with heat indicator | |||
has failed. | opens and power to the elements is | ||
ON. | |||
| shut off. If the contactor fails to close, | ||
|
| ||
|
| no power is supplied to the elements. | |
|
| Determining which component has | |
|
| failed is beyond the scope of operator | |
|
| troubleshooting. Call FASC. | |
5.2.2 Error Messages and Display Problems |
| ||
|
|
| |
Problem | Probable Causes | Corrective Action | |
CM III.5 display is in |
| CM III.5 computers may be | |
| programmed to display in either | ||
wrong temperature | Incorrect display option programmed. | Fahrenheit or Celsius. Refer to the | |
scale (Fahrenheit or | separate Frymaster Fryer Controllers | ||
| |||
Celsius). |
| User's Manual for instructions on | |
|
| changing the display. | |
|
| Verify that the drain valve is fully | |
CM III.5 |
| closed. The fryer will not function if | |
| the drain valve is not fully closed. If | ||
or | Open drain valve or problem with | ||
the drain valve is fully closed, the | |||
Digital Controller | latching circuitry. | ||
problem is within the latching | |||
display shows . |
| ||
| circuitry and is beyond the scope of | ||
|
| ||
|
| operator troubleshooting. Call FASC. |