Frymaster H50 1.3Cleaning the Gas Valve Vent Tube, 1.4Checking the Burner Manifold Gas Pressure

Models: H50

1 100
Download 100 pages 165 b
Page 10
Image 10
1.3Cleaning the Gas Valve Vent Tube

3.After servicing is complete, reconnect the unit to the gas supply, reattach restraining devices, and plug in the electrical cords.

1.3Cleaning the Gas Valve Vent Tube

1.Set the fryer power switch and the gas valve to the OFF position.

2.Carefully unscrew the vent tube from the gas valve. NOTE: The vent tube may be straightened for ease of removal.

3.Pass a piece of binding wire (.052 inch diameter) through the tube to remove any obstruction.

4.Remove the wire and blow through the tube to ensure it is clear.

5.Reinstall the tube and bend it so that the opening is pointing down.

1.4Checking the Burner Manifold Gas Pressure

1. On non-CE fryers only, ensure that the gas valve knob is in the OFF position.

Honeywell

ON

OFF

2. Remove the pressure tap plug from the gas valve assembly.

Pressure Tap Plug

Typical Non-CE

Typical CE Valve

Valve Assembly

Assembly

3.Attach a manometer or pressure gauge to the pressure tap hole.

1-5

Page 10
Image 10
Frymaster H50 manual 1.3Cleaning the Gas Valve Vent Tube, 1.4Checking the Burner Manifold Gas Pressure