Frymaster H50 manual On non-CEfryers only, place the gas valve in the ON position

Models: H50

1 100
Download 100 pages 165 b
Page 11
Image 11
4.On non-CE fryers only, place the gas valve in the ON position.

4.On non-CE fryers only, place the gas valve in the ON position.

5.Place the fryer power switch in the ON position. When the burner has lit and burned steadily for at least one minute, compare the gas pressure reading to the pressure for the corresponding gas in the appropriate table below. The tables list the burner manifold gas pressures for each of the gas types that can be used with this equipment.

CE Standard

Burner Manifold Gas Pressures

 

Pressure (mbar)

 

 

 

 

Single

Dual

Gas

Vat

Vat

Natural Gas Lacq

7

7

(G20) under 20 mbar

 

 

Natural Gas Gronique *

10

10

(G25) under 25 mbar

 

 

Natural Gas Gronique

10

10

(G25) under 20 mbar

 

 

Butane/Propane

17

17

(G30) at 28/30 or 50 mbar

 

 

Propane

20

20

(G31) under 37 or 50 mbar

 

 

* Belgian G25 = 7,0 mbar (single or dual)

Non-CE Standard

Burner Manifold Gas Pressures

 

 

Gas

Pressure

 

 

 

 

 

Natural

3" W.C.

 

 

 

 

 

0.73 kPa

 

 

 

 

 

 

 

 

 

 

 

Propane

8.25" W.C.

 

 

 

 

 

2.5 kPa

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6.To adjust the burner gas pressure, remove the cap from the gas valve regulator and adjust it to the correct pressure.

Non-CE

CE

Valve

Valve

GAS VALVE REGULATOR CAP

1-6

Page 11
Image 11