Verify high-limit controls (continued)
5 Equipment alert
Be extremely careful during this procedure.
Test the first (internal) high- limit control.
If you decided to test a full vat or the
If you decided to test the left- hand side of a
The right display will alter- nate between displaying “Hi- Limit” and the current oil temperature until the tempera- ture reaches 410°F (210°C). When the temperature reaches 410°F (210°C), the display will alternate between
If the display alternates be- tween
When the test is finished, reset the computer by press- ing the on/off key to turn the computer off, and then press the on/off key again to turn the computer on.
6Test second (mechanical)
If you are testing a full vat or the
If you are testing the
The display will alternate between
If the display alternates be- tween
Press the on/off button to clear the second test and turn the computer off.
©McDonald’s Corporation · Planned Maintenance Manual · Revised June 2008 | Page 2 of 3 |
Frymaster Fryer All models using an M2000 Computer
Quarterly