Frymaster M2000 Replace filter o-rings, Quarterly FR 2 Q3, Remove filter pan, Replace O-ring

Models: M2000

1 26
Download 26 pages 43.15 Kb
Page 19
Image 19
Replace filter o-rings

 

Replace filter o-rings

 

 

 

Quarterly

 

 

 

FR 2 Q3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Why

To keep the fryer’s filter pump in working order

 

 

 

 

 

Time required

2 minutes to prepare

5 minutes to complete

 

 

 

 

 

Time of day

At open; the fryer must be cool

For 24-hour restaurants: During a low-volume period

when the fryer can be turned off

Hazard icons

Tools and supplies

O-rings for the filter

Flat tip screwdriver

pump

 

Frymaster

Pi

Fryer All models using an M2000 Computer

 

Procedure

1Prepare fryer for procedure.

Check to make sure the fryer is cool. This procedure should be done only when the fryer is cool and the filter pan is empty.

2Remove filter pan.

Pull the filter pan out of the cabinet.

3Replace O-ring.

Remove the O-ring from the pan nozzle. Replace the O- ring with a new O-ring. O- rings can be purchased from your local authorized servicer.

Use only the manufacturer’s replacement O-ring. These rings are manufactured spe- cifically for use with hot cooking oils. Generic O-rings cannot be used for this pur- pose.

4Reinstall filter pan.

Reinstall the pan into the fryer cabinet.

Quarterly

FR 2 Q3

©McDonald’s Corporation · Planned Maintenance Manual · Revised June 2008

Page 1 of 1

Page 19
Image 19
Frymaster M2000 Replace filter o-rings, Quarterly FR 2 Q3, Procedure 1 Prepare fryer for procedure, Remove filter pan