Frymaster OCF30 operation manual Australian Requirements

Models: OCF30

1 46
Download 46 pages 8.96 Kb
Page 11
Image 11
2.1.3 Australian Requirements

2.1.3 Australian Requirements

To be installed in accordance with AS 5601 / AG 601, local authority, gas, electricity, and any other relevant statutory regulations.

2.2Power Requirements

Three (3) Phase Requirements

MODEL

VOLTAGE

WIRE

SERVICE

 

 

 

FPEL14

208

3

FPEL14

240

3

FPEL14

480

3

FPEL14

220/380

4

FPEL14

240/415

4

FPEL14

230/400

4

FPEL17

208

3

FPEL17

240

3

FPEL17

480

3

FPEL17

220/380

4

FPEL17

240/415

4

FPEL17

230/400

4

MINIMUM WIRE

AMPS

 

SIZE

 

(per leg)

AWG

 

(mm)

 

 

6

 

(4.11)

39

6

 

(4.11)

34

8

 

(2.59)

17

6

 

(4.11)

21

6

 

(4.11)

20

6

 

(4.11)

21

6

 

(4.11)

48

6

 

(4.11)

41

6

 

(4.11)

21

6

 

(4.11)

26

6

 

(4.11)

24

6

 

(4.11)

25

NOTICE

If this appliance is permanently connected to fixed wiring, it must be connected by means of copper wires having a temperature rating of not less than 167°F (75°C).

Manual background DANGER

This appliance must be connected to a power supply having the same voltage and phase as specified on the rating plate located on the inside of the appliance door.

Manual background DANGER

All wiring connections for this appliance must be made in accordance with the wiring diagram(s) furnished with the appliance. Refer to the wiring diagram(s) affixed to the inside of the appliance door when installing or servicing this equipment.