Problem

Probable Causes

Fryer repeatedly

 

cycles on and off

Fryer is in melt-cycle mode.

when first started.

 

 

 

Fryer heats until

Temperature probe or controller has

high limit trips with

failed.

heat indicator ON.

 

Fryer heats until

 

high limit trips

Contactor or controller has failed.

without heat

 

indicator ON.

 

Fryer stops heating

The high limit thermostat or

with heat indicator

contactor has failed.

ON.

 

Corrective Action

This is normal behavior. Refer to the separate YUM! Wingstreet Controller Manual.

Turn fryer off and call FASC.

Call FASC.

Call FASC.

6.2.2 Filtration Problems

Problem

Probable Causes

 

A. Power cord is not plugged in or

 

circuit breaker is tripped.

 

 

 

B. Pump motor has overheated

 

causing the thermal overload

Filter pump won't

switch to trip.

 

start.

 

 

 

 

C. Blockage in filter pump.

 

Test: Close the drain valve and

 

pull the filter pan out from the

 

fryer. Activate the pump. If the

 

pump motor hums for a short time

 

and then stops, the probable cause

 

is blockage of the pump itself.

Corrective Action

A. Verify that the power cord is fully plugged in. If so, verify that circuit breaker is not tripped.

B. If the motor is too hot to touch for more than a few seconds, the thermal overload switch has probably tripped. Allow the motor to cool at least 45 minutes then press the Pump Reset Switch.

C. Pump blockages are usually caused by sediment buildup in the pump due to improperly sized or installed filter paper and failure to use the crumb screen. Call FASC.