Fujitsu BS2OSD manual Product use

Models: BS2OSD

1 47
Download 47 pages 25.84 Kb
Page 35
Image 35

*4 Innovations in IMON V3.0

*4 With IMON V3.0, delivery units that are parked on a key-formatted

*4 pubset can be installed on a non-key-formatted pubset.

*4 Previously, the statement GENERATE-IDF displayed all delivery

*4 units. Only the installed delivery units are now offered in the

*4 dialog.

*4 As of IMON V3.0, the TASKLIB and MACROLIB can also be installed

*4 under a default user ID (DEFLUID system parameter) other than

*4 TSOS. The parameter ZVDEFSUP in the IMON parameter file must be

*4 set to "Y" for this.

*4 Important note: if the parameter ZVDEFSUP is set to "Y", the two *4 files $TSOS.TASKLIB and $TSOS.MACROLIB must be copied under the *4 default user ID and deleted from under $TSOS before the next IMON *4 installation.

*4 In addition, IMON V3.0 also contains preliminary functions for

*4 future hardware platforms and BS2000/OSD-BC versions.

CRTE-BASYS:

*4 The subsystem CRTEBASY of CRTE-BASYS V1.6 is available as a run- time environment for BS2000-internal applications. This subsystem should only be preloaded if this is recommended in the Release Notice of another installed product.

By default the subsystem is loaded in upper class 4 memory. As an alternative, the subsystem can also be loaded below 16 MB in class 4 memory using the SYSSSC file with the extension LOW

*4 (SYSSSC.CRTE-BASYS.016.LOW) if there is enough space available there.

In addition, IMON copies the IC@RTSXS, IC@STLNK and IC@ULINK mod-

*4 ules from the SYSLNK.CRTE-BASYS.016.CLIB library to CLIB. If no $.CLIB file exists on the source system it is created by IMON. This $.CLIB can be used for programs which were compiled with C V2.0 or earlier.

The compatibility library SYSLNK.ILCS is also installed with

CRTE-BASYS.

If a default user ID other than TSOS is used (DEFLUID system pa- rameter), it should be noted that during installation of CRTE- BASYS not all libraries are automatically installed under the de- fault user ID. When installation with IMON is completed, the $TSOS.CLIB file must be copied to $<default_user_ID>.CLIB.

3.4Product use

All conversion activities for BS2000/OSD-BC V6.0 are described in the manual BS2000/OSD-BC V6.0 Migration Guide.

An update to BS2000/OSD-BC V6.0 is possible on the basis of BS2000 versions OSD-BC V4.0 and V5.0. A first-time installation of BS2000/OSD-BC V6.0 must be made for all earlier BS2000 ver- sions. Configurations with V4.0 and V5.0 are possible with a shared pubset network using MSCF.

Page 34

Page 35
Image 35
Fujitsu BS2OSD manual Product use