June 2007 Troubleshooting your CallPilot system
1005r Server Maintenance and Diagnostics 33
A: Drive Error No response from the disk drive.
CMOS Battery Low The battery is losing power. Replace
the battery soon.
CMOS Display Type Wrong The display type is different from that
stored in CMOS. Check Setup to make
sure the type is correct
CMOS Checksum Bad The CMOS checksum is incorrect.
CMOS memory can be corrupted. Run
Setup to reset the values.
CMOS Settings Wrong The CMOS values are not the same as
the last boot. Either these values are
corrupted or the battery failed.
CMOS Date/Time Not Set The time or date values stored in
CMOS are invalid. Run Setup to set the
correct values.
DMA Error An error occurred during the read/write
test of the DMA (Direct Memory
Access) controller.
FDC Failure An FDC Failure error occurred while
trying to access the diskette drive
controller.
HDC Failure An error occurred trying to access the
hard disk controller.
Checking NVRAM.... The NVRAM (Non-Volatile Random
Access Memory) is being checked to
see if it is valid.
Error message Description